6.2 Programming a Light Cycle

Press ENTER. The controller menu will open.
1. Press the UP/DOWN keys to locate "LIGHT CYCLE" and
press ENTER. The Light Cycle Screen will open. In this
screen, the hour indication behind "ON" blinks (Figure 8A).
2. Press the UP/DOWN keys to select the hour on which
the lights must be activated and press ENTER to confirm
your choice.
3. Use the same procedure to set the minute (Figure 8B)
on which the lights must be activated and the hour
(Figure 8C) and minute (Figure 8D) on which the lights
must be deactivated.

6.3 Setting Safety Shutdown Temperature

Note: The default shutdown temperature is set at 35°C/95°F.
Note: After a shutdown, a manual reset may be required.
Note: If "T:" or "RH:" read "N/A", the plug of the sensor is not (fully) plugged in. Plug the sensor in completely.
1. Press ENTER. The controller menu will open.
2. Press the UP/DOWN keys to locate "SHUTDOWN TEMP" and press ENTER. The Shutdown Temperature
Screen opens.
3. Press the UP/DOWN keys to increase or decrease the temperature.
4. Press ENTER to confirm.
Once the shutdown temperature is reached, the controller will automatically shut down all the lights.
The red LED will be illuminated and the blue LED will be off. The red LED will remain illuminated until the
room temperature has decreased at least 2°C/4°F below the safety shutdown temperature or the safety
shutdown temperature is changed. If the red LED remains on after both scenarios, a manual reset will
need to be performed.
6.4 Activate or Deactivate the Systems Manually or Set Automatic Mode
WARNING! ALWAYS disconnect the driver from the main power supply.
Note: The On and Off Modes are included to allow for maintenance, replacement or testing of systems.
Note: When the controller Output Mode is set to "ON" or "OFF", the temperature safety features of the controller
will not work. The Output Mode must be set to "Auto" to engage the temperature safety shutdown.
Press ENTER, the controller menu will open.
5. Press the UP/DOWN keys to locate "output mode" and press ENTER.
6. Press the UP/DOWN keys to switch between "AUTO", "ON" and "OFF. "
a. Select "ON" to turn all the systems on. This setting will ignore temperature safety settings.
(see section 6.3)
b. Select "OFF" to turn all the systems off.
c. Select "AUTO" to follow the programmed light cycle (see section 6.2) and temperature safety
settings. (see section 6.3)
4. Press ENTER to confirm your choice.
6.5 Resetting the Controller to Factory Settings
The factory reset will return all values to factory settings.
1. Press ENTER, the controller menu will open.
2. Press the arrow keys to locate "FACTORY RESET" and press ENTER. The Factory Reset Screen opens.
3. Press the arrow keys to switch to "YES" and press ENTER.
The controller is now reset to factory settings.