Information On This Document; Symbols Used - pizzato CS DM-20 Serie Manual De Instrucciones

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 13

1 INFORMATION ON THIS DOCUMENT

1.1 Function
These operating instructions provide information on installation, connection and safe
use for the following articles: CS DM-20••••.
1.2 Target audience
The operations described in these operating instructions must be carried out by qua-
lified personnel only, who are fully capable of understanding them, and with the tech-
nical qualifications required for operating the machines and plants in which the safety
devices are to be installed.
1.3 Application field
These instructions apply exclusively to the products listed in paragraph Function, and
their accessories.
1.4 Original instructions
The Italian language version is the original set of instructions for the device. Versions
provided in other languages are translations of the original instructions.

2 SYMBOLS USED

This symbol indicates any relevant additional information
Attention: Any failure to observe this warning note can cause damage or malfun-
ction, including possible loss of the safety function.
3 DESCRIPTION
3.1 Device description
The safety device described in this manual is defined according to the Machinery
Directive 2006/42/EC as logic component for safety functions.
The safety modules to which these usage instructions refer are devices specifically
designed and manufactured for use on industrial machines. The safety function is a
type IIIA two-hand control acc. to EN ISO 13851. Pressing both of the two enabling
buttons within the predefined time range for synchronised actuation, this activates the
safety output. Upon releasing at least one of the buttons, the safety output is deactiva-
ted within the specified release time.
3.2 Device functions
This device can be used as a module for two-hand control devi-
ces acc. to EN ISO 13851 (Type III A) or as a module for synchroni-
sm control, in safety circuits up to category SIL 1 acc. to EN 62061,
up to to Cat. 1 / PL c acc. to EN ISO 13849-1:2015
- Input with 2 channels.
- Output contacts: 2 NO safety contacts.
- Connection of input channels of opposite potentials.
- Short circuit detection function of the control elements by means of safety system
with self-monitoring and redundancy.
- LED indicators for switching state of the channels 1, 2 and for the power supply
voltage.
- Without muting input, no bridging of the safety function.
- Screw terminals or plug-in terminals with screw connections or spring terminals (de-
pending on the model).
- Snap-mounting on DIN rails.
3.3 Intended use of the device
- The device described in these operating instructions is designed to be applied on
industrial machines.
- The direct sale of this device to the public is prohibited. Installation and use must be
carried out by qualified personnel only.
- The use of the device for purposes other than those specified in these operating
instructions is prohibited.
- Any use other than as expressly specified in these operating instructions shall be
considered unintended by the manufacturer.
- Also considered unintended use:
a) using the device after having made structural, technical, or electrical modifications
to it;
b) using the product in a field of application other than as described in paragraph
TEChNICAL DATA.
e-mail:
Pizzato Elettrica Srl
web site: www.pizzato.com
via Torino, 1
36063 MAROSTICA (VI)
Phone:
ITALY
4 OPERATION
4.1 Operating diagram
t
t
t
t
t
SN
A
SN
A
R1
Legend:
t
> time interval for synchronised actuation
SN
t
: Response time
A
t
: Release time
R1
t
: Release time in absence of power supply
R
4.2 Wiring diagrams
Circuit with two-hand control device type III A according to EN ISO 13851
A1
S13
Button 2
Movable guard monitoring with automatic start and simultaneity between channels <
Device 1
4.3 Increase of number and load capacity of contacts
If necessary the number and the load capacity of output contacts can be increased by
using external contactors with forcibly guided contacts
Feedback circuit for external contactors
L / +
N / -
4/18
+39.0424.470.930
A1/A2
S13/S14
S23/S24
13/14,23/24
t
t
t
t
t
t
R
SN
A
A
R1
R1
Feedback circuit
Y1
Y2
CS DM-20
S14
S23
S24
A2
Button 1
0.5 s
Feedback circuit
A1
Y1
Y2
CS DM-20
S13
S14
S23
S24
A2
Device 2
Guard closed
K4
F
F
K3
Y1
Y2
13
23
14
24
K3
K4
ZE FOG83A22-EU
Tabla de contenido
loading

Tabla de contenido