D 600 AP / D 600 AP PLUS / D 600 APG / D 600 APG PLUS
Cuadro de averías motor Deutz
Código
Código
parpadeo
SCR main relay (primary side); powerstage over
1099
6-7-6
temperature
1100
6-7-6
SCR main relay (primary side); short circuit to battery
1101
6-7-6
SCR main relay (primary side); short circuit to ground
1102
6-7-5
SCR heater relay DEF supply line primary side; open load
1104
6-7-5
SCR-heater DEF supplyline; short circuit to battery
1105
6-7-5
SCR-heater DEF supply line; short circuit to ground
SCR heater relay DEF supplymodule primary side; open
1106
6-7-2
load
1108
6-7-2
SCR heater DEF supplymodule; short circuit to battery
1109
6-7-2
SCR heater DEF supplymodule; short circuit to ground
1110
6-7-1
SCR tank heating valve primary side; open load
1112
6-7-1
SCR Tank heating valve; short circuit to battery
1113
6-7-1
SCR Tank heating valve; short circuit to ground
1117
6-6-6
Pump motor not available for actuation
1118
6-6-6
Urea pump motor; open load
1120
6-6-6
Urea pump motor; short circuit to battery
1121
6-6-6
Urea pump motor; short circuit to ground
Supply module DEF, DEF pressure above upper physical
1122
6-6-5
threshold
Urea supply module pressure sensor; physical range
1123
6-6-5
check low (defect pressure sensor)
1124
6-6-5
Urea pump pressure sensor; high signal not plausible
1125
6-6-5
Urea pump pressure sensor; low signal not plausible
Signal error for CAN message
1126
6-6-5
No detail informationen!
Sensor error urea pump pressure; signal range check
1127
6-6-5
high
Sensor error urea pump pressure; signal range check
1128
6-6-5
low
1129
6-6-7
SCR reversal valve; open load
1130
6-6-7
SCR reversing valve; over temperature
1131
6-6-7
SCR reversal valve; short circuit to battery
1132
6-6-7
SCR reversing valve; short circuit to ground
1135
6-6-9
DEF tank, DEF temperature in DEF tank is to high.
DEF tank, DEF temperature below lower physical
1136
6-6-9
threshold
1137
6-6-9
Tank temperature signal error for CAN message
Sensor error urea tank temperature: short circuit to
1138
6-6-9
battery
Sensor error urea tank temperature; short circuit to
1139
6-6-9
ground.
1157
2-2-8
Water in fuel level prefilter; maximum value exceeded
Zerofuel calibration injector 1 (in firing order); maximum
1158
7-7-2
value exceeded
Zerofuel calibration injector 2 (in firing order); maximum
1159
7-7-2
value exceeded
Zerofuel calibration injector 3 (in firing order); maximum
1160
7-7-2
value exceeded
Zerofuel calibration injector 6 (in firing order); maximum
1163
7-7-2
value exceeded
Zerofuel calibration injector 1 (in firing order); minimum
1164
7-7-2
value exceeded
Zerofuel calibration injector 2 (in firing order); minimum
1165
7-7-2
value exceeded
Zerofuel calibration injector 3 (in firing order); minimum
1166
7-7-2
value exceeded
Zerofuel calibration injector 4 (in firing order); minimum
1167
7-7-2
value exceeded
Descripción en Inglés
Código
Código
parpadeo
Zerofuel calibration injector 5 (in firing order); minimum
1168
7-7-2
value exceeded
1170
5-5-5
Internal software error ECU
1180
3-1-8
Physical range check high for battery voltage
1181
3-1-8
Physical range check low for battery voltage
1183
2-2-6
Air inlet filter sensor out of physical range check
1187
7-8-4
Bad quality of reduction agent detected
Physical range check high for exhaust gas temperature
1193
5-5-6
upstream turbine
Physical range check low for exhaust gas temperature
1194
5-5-6
upstream turbine
HMI engine derate service state
1219
7-8-6
DPF wasn´t regenerated, power reduction phase 1
(manuell regeneration request)
HMI engine derate stop state
1220
7-8-6
DPF wasn´t regenerated, power reduction phase 2
(manuell regeneration request)
Camshaft- and Crankshaft speed sensor signal not
1222
2-1-2
available on CAN
Actuator EGR-Valve (2.9;3.6) or Throttle-Valve
1223
5-9-4
(4.1;6.1;7.8); open load
Actuator EGR-Valve (2.9;3.6) or Throttle-Valve (6.1,7.8);
1224
5-9-4
over current
EGR-Valve (2.9;3.6) or Throttle-Valve (4.1;6.1;7.8); short
1226
5-9-4
circuit to battery
EGR-Valve (2.9;3.6) or Throttle-Valve (4.1;6.1;7.8); short
1227
5-9-4
circuit to battery
EGR-Valve (2.9;3.6) or Throttle-Valve (4.1;6.1;7.8); short
1228
5-9-4
circuit to ground
EGR-Valve (2.9;3.6) or Throttle-Valve (4.1;6.1;7.8); short
1229
5-9-4
circuit to ground
Actuator error EGR-Valve (2.9;3.6) or Throttle-Valve
1230
5-9-4
(4.1;6.1;7.8); Overload by short-circuit
1231
5-9-4
Power stage overtemperature due to high current.
actuator AGR valve (2.9;3.6) throttle valve (4.1;6.1;7.8);
1232
5-9-4
Voltage below threshold.
1239
7-8-8
UB7; Short circuit to battery error of actuator relay 7
1241
1-7-6
UB6; Short circuit to ground actuator relais 6
1242
7-9-1
UB7; Short circuit to ground actuator relay 7
Burner Control; Air Line - Blocked Air Pump; air lines
1247
8-6-2
blocked
Burner Control; Air Pump - CAN Lost Air Pump; CAN
1248
6-9-5
communication lost
Air pump; CAN communication interrupted no purge
1249
6-9-5
function available
1250
6-9-5
Air Pump; internal error
1252
6-9-5
Air Pump; operating voltage error
Air inlet EPV - pressure too low Air pressure glow plug
1254
8-5-8
flush line; below limit
Burner Control; Flame lost max Burner operation is
1255
8-5-7
interrupted too often
1257
8-5-3
HCI dosing valve (DV1); blocked open
Burner Control; HFM - Electrical Fault
1258
8-5-9
HFM sensor; electrical fault
Burner Control; HFM - Plausibilitätsfehler 1
1259
8-5-9
Amount of air is not plausible to pump speed
Burner Control Air Pump; over current
1261
6-9-5
Air pump electrically overloaded
Burner Control; Shut-off Valve - Blocked closed Burner
1262
8-5-4
Shut Off Valve; blocked closed