- It is possible to cascade several devices to be managed together (if they are in the same DMX address)
or separately (if they are in different DMX addresses).
Use an XLR cable to connect the device's DMX IN to the DMX OUT of the DMX controller when the device
is the first element in the chain. Alternatively, connect to the DMX OUT of the preceding element in the
lighting chain of your installation.
You can also supply power from one light to the next in the chain in the same way as shown in the picture.
DMX CONTROLLER
POWER IN
POWER IN
To interconnect them, you must use XLR cables with the following configuration:
ES
1
Masa
3
XLR macho (vista pines)
IMPORTANT: the complete length of cable used to interconnect the devices in a line must not exceed 100
meters. To prevent line interference, it is recommended that an electric terminator consisting of a 120 Ω
PT
resistor be placed at the last element in the chain between pins 2 and 3 of the XLR DMX OUT connector of
1
the last element.
Massa
3
XLR macho (vista pinos)
- Connect all the elements to the power supply and turn them on to start using them.
MASTER SLAVE CONTROL
The master-slave function allows several lights to operate in synchronization (same color and same move-
ments) without the need of a DMX controller.
- Cascade the PAR-70L you want to use.
- Select the slave mode (A001) on every light except the one you want to be the master ("MASTER"). These
lights are referred to as slave lights (SLAVE.
- At the MASTER light select any of the operating modes other than DMX control.
GND
POWER IN
~110-240 V AC. 50/60 Hz FUSE: 5 A
POWER CONSUMPTION: 60 W
MODE
SET
DMX IN
DMX OUT
DMX IN
DMX OUT
GND
POWER IN
~110-240 V AC. 50/60 Hz FUSE: 5 A
POWER CONSUMPTION: 60 W
MODE
SET
DMX IN
DMX OUT
DMX IN
DMX OUT
GND
POWER IN
~110-240 V AC. 50/60 Hz FUSE: 5 A
POWER CONSUMPTION: 60 W
MODE
SET
DMX IN
DMX OUT
DMX IN
EN
2
Señal +
Ground
Señal -
FR
2
Sinal +
Masse
Sinal -
XLR mâle (vue broches)
1
2
Signal +
3
Signal -
Male XLR (pin view)
1
2
Signal +
3
Signal -
- 4 -
BAR-73L
LED BAR 24 x 3 W
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION : SHOCK HAZARD - DO NOT OPEN
RISK OF FIRE-REPLACE FUSE AS MARKED
POWER OUT
4 A MAX.
BAR-73L
LED BAR 24 x 3 W
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION : SHOCK HAZARD - DO NOT OPEN
RISK OF FIRE-REPLACE FUSE AS MARKED
POWER OUT
4 A MAX.
POWER OUT
BAR-73L
LED BAR 24 x 3 W
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION : SHOCK HAZARD - DO NOT OPEN
RISK OF FIRE-REPLACE FUSE AS MARKED
POWER OUT
4 A MAX.
POWER OUT