System
Effective frequency range
Recommended amplifier power
Transducers
Physical
Recommended cut out diameter
Dimensions (WxHxD)
1
10dB below the sound pressure level at specified sensitivity
2
6dB below the sound pressure level than that at the direction of maximum level, Average from 1 kHz to 4 kHz.
3
Measured on-axis, far field and referenced to 1 meter by inverse square law. Average from 100 Hz to 10 kHz.
4
Calculated from sensitivity and power handling specifications, exclusive of power compression
83 Hz-20 kHz (-10dB)
1
Coverage angle
158°x158° (HxV)
2
Power handling
30 W RMS / 120 W Peak
Sensitivity
84 dB (1W/1m)
3
Maximum SPL
99 dB continuous / 105 dB peak
4
Power options
100V: 30W / 15W
60 W RMS
Ways
1
Driver
3" woofer
Nominal impedance
667Ω / 333Ω
Connection type
Spring terminals
Power type selector
Changing the position of the terminals
Installation options
Wall or false ceiling
Enclosure material
ABS
Grille material
Aluminium, paintable
Finished color
White (RAL 9003)
147 x 95 mm / 5.79"x3.74"
Required depth
80 mm / 3,14"
Ceiling thickness
2mm / 0.078" min
40mm / 1.57" max
110 x 165 x 80 mm / 4.33 x 6.5 x 3.15 in.
Weight
0.9 kg / 1.98 lb