Specific Operating Instructions
1
2
4
5
a.) Installation
Fastening holes (4) are provided for wall mounting. The unit must be mounted against a vertical, fireproof wall with the
connections at the bottom, see above picture, left part. For outside installation the device must also be protected against
exposure to rain and direct sunlight.
b.) Functional description of the appliance
Commission device WITHOUT fence and connection to earth. The control lights flash in time to the impulses (green or
red). The device is ready for operation. If control lights do not flash, the power supply or power supply line must be
checked first. If no fault can be detected, the device should be tested by a specialist.
c.) Functional description with CONNECTED fence system (earthing + fence)
Control light
1
"OK"
Flashing green:
(1)
Control light
Flashing
2
"CHECK" (2)
red:
Connection variants:
Fence system closed:
Fence systems may be operated independent of each other at the fence connections (5 or 6).
The measured value indicated in the display (1) and the associated indicator light are nevertheless only capable of
displaying the exit exactly with maximum energy (6). If the indicator light flashes faster than once per second, the
appliance must be disconnected at once and checked by a technician before it can be used again.
Any user of electric fence systems is legally indebted to control the fence-appliance and the fence system regularly, in
accordance with the conditions of use, at least once per day.
visual check of the appliance and the fence system
-
-
measurement of the minimum voltage of 2500V at each point of the fence
This equipment carries a 3-year warranty in accordance with our Warranty Terms & Conditions!
Please see the attached Operating Instructions for safety tips, earthing, commissioning, warranty terms and
conditions and potential sources of fault!
SERVICE Addresses:
Please contact your specialist dealer
OK
CHECK
Mains plug is used as ON / OFF!
Connection to
This  energizer  shall  not  be  used  as  an  animal
6
trainer (inside a barn). 
State of fence/ earth ok = output voltage > 4000V = OK
CHECK = State of fence faulty = output voltage ≤ 4000V, see operating
instructions enclosed, possible sources of error (fig. 2, pg.5)
CHECK = State of connection to earth faulty, see operating instructions enclosed,
possible sources of error (fig. 2, pg.5) and connection to earth (pg.4)
earth
Erdung
1
2
3
4
5
230 V ~!
6
Fence system open:
3
Indicator light "OK"
Indicator light "CHECK"
Fastening holes
Earth connection
Fence connection
with reduced energy
Fence connection
with maximum energy
earth
-EN-
Version : 2017.3