Warranty - T.I.P. STEAM 35000 INV Traducción De Las Instrucciones De Uso Originales

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

Help in case of faults:
Code
Fault
1
IPM overcurrent
2
Compressor
4
Reserved
Compressor without
8
phase
16
DC link voltage too low
32
DC link voltage too high
Radiator fin temperature
64
too high
Radiant fan failure
128
temperature
257 Connection error
258 AC input without phase Input without phase
AC input voltage too
260
high
264 AC input voltage too low Input voltage too low
272 High pressure failure
IPM temperature too
288
high
Compressor current too
320
high
384 Reserved

7. Warranty

The present device was manufactured and inspected according to the latest methods. The seller warrants for
faultless material and workmanship in accordance with the legal regulations of the country in which the device
was purchased. The warranty period begins with the day of the purchase and is subject to the provisions below:
Within the period of warranty, all defects which are to be attributable to defective materials or manufacturing will
be eliminated free of charge. Any complaints are to be reported immediately upon their detection.
The warranty claim becomes void in the case of interventions undertaken by the purchaser or by third parties.
Damage resulting from improper handling or operation, incorrect setting-up or storage, inappropriate connection
or installation or Acts of God or other external influences are excluded from warranty.
Parts being subject to wear and tear, such as the pump wheel (impeller), mechanical shaft seals, membranes and
pressure switch are excluded from warranty.
All parts were manufactured using maximum care and high-quality materials and are designed for a long lifecycle.
It should be understood, however, that the wear and tear depends on the kind of use, the intensity of use and the
internals of maintenance. Complying with the installation and maintenance information contained in the present
operating instructions will therefore considerably contribute to a long lifecycle of these wearing parts.
In case of complaints, we reserve the option of repairing or replacing the defective parts or replace the entire de-
vice. Replaced parts will pass into our property.
Claims for liquidated damages are excluded unless they are caused by wilful acts or negligence on the side of the
manufacturer.
The warranty does not provide for any claims beyond those referred to above. The warranty claim has to be evi-
denced by the purchaser in the form of the submission of the sales receipt. The present warranty commitment is
valid in the country in which the device was purchased.
Possible cause
IPM module failure
Compressor
The cable for the compressor is
interrupted/badly connected
Input voltage too low/PFC module
error
Input voltage too high/PFC module
error
Fan motor failure/air duct blockage Check fan motor/air duct
Cooling fin temperature sensor
short circuit or interruption of the
circuit
Inverter module does not receive
the command from the PCB
Input three-phase unbalanced
Compressor pressure too high
(reserved)
Fan motor failure/air duct blockage Check fan motor/air duct
The current of the compressor
wiring is too high/ driver and
compressor do not fit together
12
Remedy
Replace the inverter module
Replace the compressor
Check the wire connection of the
compressor
Check input voltage/replace module
Replace the inverter module
Replace the inverter module
Check the connection between module
and PCB
Check the cable connection
Check input of 3-phase voltage
Check input voltage
Replace the inverter module
27
Tabla de contenido
loading

Este manual también es adecuado para:

Steam 45000 inv

Tabla de contenido