Problem
The thermal overload
protector cuts out
repeatedly.
The air receiver
pressure drops when the
compressor shuts off .
There is excessive
moisture in the air
discharge.
Air is leaking from the
compressor.
The compressor runs
continuously
The compressor vibrates. The compressor mounting bolts are loose. Tighten mounting bolts.
The air output is lower
than normal.
Battery cannot be
installed
2. Charger
Symptom
The charge indicator lamp
rapidly fl ickers purple, and
battery charging doesn't
begin.
The charge indicator lamp
blinks red, and battery
charging doesn't begin.
24
Possible Cause
A poorly ventilated room is causing the
motor to overheat.
The connections are loose or leaking
(fi ttings, tubing, etc.).
The drain valve is loose.
The check valve is leaking.
There is excessive water in the tank.
The humidity is high.
The hose connection is loose or improperly
sealed.
The air hose is broken or damaged.
The drain valve is open.
The power switch is defective.
The usage is excessive.
The inlet valves are broken.
The connections are leaking.
Attempting to install a battery other than
that specifi ed for the tool.
Possible cause
The battery is not inserted all the way.
There is foreign matter in the battery
terminal or where the battery is attached.
The battery is not inserted all the way.
The battery is overheated.
Remedy
Move the compressor to well-ventilated
area.
Check all the connections with soapy water
and look for bubbles. Tighten any loose
conections until the leak stops.
Tighten the drain valve.
Take the compressor to a service center.
WARNING
Do not disassemble check valve
while air is in tank - empty the
all the air out of the tank before
dissasembly.
Drain the tank to remove water.
Move the compressor to an area of less
humidity or use an air line fi lter to reduce
moisture discharge in the tank.
Ensure connections are sealed with thread
sealing tape and tightened.
Replace the air hose.
Ensure the drain valve is closed.
Take the compressor to a service center.
Decrease the amount of tool run-time; the
compressor is not large enough to supply
the air requirement of the tool.
Take the compressor to a service center.
Apply thread sealing tape to fi tting and
tighten.
Please install a multi volt type battery.
Remedy
Insert the battery fi rmly.
Remove the foreign matter.
Insert the battery fi rmly.
If left alone, the battery will automatically
begin charging if its temperature
decreases, but this may reduce battery
life. It is recommended that the battery be
cooled in a well-ventilated location away
from direct sunlight before charging it.
Tabla de contenido