Description Of Functions - Stagnoli ACNSEM3L Manual Del Usuario

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

DESC DESCTIPTION OF TIMING PARAMETERS
(Green timing light 1) = timing of green for traffic light 1 expressed in seconds, therefore also
TV1
timing of red for traffic light 2
(Green timing light2) = timing of green for traffic light 2 expressed in seconds, therefore also
TV2
timing of red for traffic light 1.
(Area clearance timing) = period preceding the color switch in which both traffic lights are red,
TSG
which allows cars to clear the area.
(Yellow light time) = if the system is regulated to a 3-light setup, DIP2 =1 sets the yellow time.
TAR
Otherwise with DIP2=0 and DIP5=1, TAR will be used to setup the blinking timing.
(Mixed Logic Time): with DIP1 = 2, set the timing for the light change in the case there are no
TMI
bookings. After the value 240. the scale varies from 1 to 60 seconds.
(Functioning Logic):
DIP1
0. On booking with control devices
1. Timed
2. Mixed Logic
For additional details on the functioning logics see the following page
(Traffic light with 3 lights):This function determines whether the specified traffic light has two or
DIP2
three lights.
0 = 2-light traffic light
1 = 3-light traffic light
(Behavior with resting lights with DIP1 = 0):
DIP3
0. All lights turned off
1. Light 1 green, light 2 red
2. Light 1 red. light 2 green
3. Both lights 1 and 2 red
(Behavior in alarm state) = Alarm state is activated only once input3 is sollicited.
DIP4
0. Both lights blink red
1. Light 1 green, light 2 red
2. Light 1 red, light 2 green
3. Both lights red
ATTENTION: the relative clearing or orange light times will be executed before switching to
alarm state
(Blinking before switching light)
DIP5
0. No blinking during TAR; if DIP2 = 0, thus the traffic lights with two lights are selected, the
lights' colors won't change
1. Blinking active before switching lights, if DIP2 = 0, the TAR icon in the Time menu then sets
the blinking time
(INPUT 1 behavior) =
DIP6
0. N.O. Input
1. N.C. Input
(INPUT 2 behavior) =
DIP7
0. N.O. Input
1. N.C. Input
(INPUT 3 emergency behavior) =
DIP8
0. N.C. Input
1. N.O. Input

DESCRIPTION OF FUNCTIONS

Default: 10sec
Min: 1sec
Max: 240sec
Default: 10sec
Min: 1sec
Max: 240sec
Default: 10sec
Min: 0sec
Max: 240sec
Default: 0sec
Min: 0sec
Max: 15sec
IT
Default: 120sec
Min: 30sec
Max: 840sec
EN
Default: 0
FR
Default: 0
Default: 3
ES
Default: 0
DE
Default: 0
Default: 0
Default: 0
Default: 0