Attaching the FW2000e to the wall mount bracket
1. Remove the installation handle and unplug the PoE cable from the PoE injector.
2. Attach a ground wire to the back of the device with the ground screw.
3. Place M6 external locking washers on four M6 21mm bracket mount bolts.
4. Attach the device to the wall mount bracket using a hex driver to tighten the
bolts to 2.0 Nm (1.48 ft/lb).
M5 10mm ground
screw / washer
M6 21mm bracket
mount bolt and
washer
14