Intended Use; Functional Description; Installation - Dustcontrol S34000 Traducción Del Manual De Instrucciones De Servicio Original

Ocultar thumbs Ver también para S34000:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 29
Always carry out a filter cleaning and empty the compressed air tank before detaching the collection device from the filter unit. All
handling of the collected material must comply with the relevant regulations.
Inspection
Regularly check the device for damage and wear. If damage occurs, these must be repaired by a Dustcontrol service technician
or by a service workshop authorized by Dustcontrol.

Intended use

Dustcontrol's filter cyclones are used to filter dust that arises in an industrial environment.
The filter cyclone is connected to a piping system provided by Dustcontrol. The system is in turn connected to a vacuum
generator.

Functional description

S34000 purifies the air in two steps.
In the first step, dust is separated in the cyclone. The air is taken in tangentially in the filter cyclone and begins to circulate
strongly. This causes the particles to be pressed out against the mantle surface and then fall to the bottom.
In the second step, the air passes through a filter that separates 99.9% of particles from size 0.3 µm. Normally, the air is then led
out of the room.
The filters are automatically cleaned after a signal from the control system by means of an air pulse in the opposite suction
direction. It is a very effective cleaning while being gentle on the filters.
S34000 is made up of modules and can be mounted in several different ways. The inlet can be turned and turned to make the
filter cyclone fit into the room.
Above: an example of how to configure a filter cyclone

Installation

The following describes how to assemble the product:
14
S34000, Art no. 99055-A
Tabla de contenido

Solución de problemas

loading