INSTRUCTIONS FOR USE
1.3
Electric connection
The appliance must be connected electrically only by qualified personnel
aware of the current regulations on installation in force.
The appliance is ready for operating in alternating current, at the voltage
shown on the "characteristic data" plate shown at the end of the booklet
and on the product (also see any connection diagram on the product).
In case of direct mains connection, an omnipolar switch must be placed
between the appliance and the mains, with a contact opening gap which
enables total disconnection in overvoltage category III conditions, in
compliance with installation regulations. The yellow/green earth wire
must not be interrupted by this switch.
The power supply cable must be H05RR-F or higher category (section
list in the following table) and must be positioned so that at no point can
it reach a temperature higher than 50 ° C in the room temperature.
MAX POWER
>= 16 A
>= 25 A
>= 32 A
Before making the connection, check that the power circuit has an
effective earthing that meets regulations in force and that the socket or
the omnipolar switch is easily reached when the appliance is installed.
The earth cable (yellow/green) connected to the product's terminal must
be longer than the others.
The manufacturer declines all liability in the event that the
regulations in force are not respected.
28 / GB
CABLE SECTION mm2
1,5 mm2
2,5 mm2
4 mm2
INSTALLATION