INSTALLATION
DANGER
Improper use can result in death or severe injuries! Only connect the device outside explosion
hazardous areas to the ISM interface of the IS530.1.
1
Unscrew the cover of the ISM interface (1) located on the IS530.1.
Push the IS530.1 completely into the holder (2) of the device.
Attach the plug on top of the ISM interface (3).
Fix the plug by pressing the rounded end of the plug (4).
Tighten the screw (5).
Check whether the plug is correctly and firmly attached to the ISM interface.
The device can now be used together with the IS530.1 in explosion hazardous areas.
CHARGING THE IS530.1
You can charge the IS530.1 via the magnetic charger port on the IS-TC1A.1.
DANGER
An incorrect procedure in explosion hazardous areas poses risk of death or severe injuries!
Only charge the IS530.1 outside of explosion hazardous areas. Do not charge the IS530.1 in
the vicinity of flammable substances.
NOTICE
Incorrect charging can cause damage to the device.
Follow the instructions in the „Charging" section of the IS530.1 operating manual.
Only charge the IS530.1 using the i.safe PROTECTOR 3.0 Magnetic Charger Cable (inclu-
ded in the IS530.1 package).
Connect the i.safe PROTECTOR 3.0 Magnetic Charger Cable to the magnetic charger port on
the IS-TC1A.1.
2
3
5
4
EN
7
Tabla de contenido
loading

Este manual también es adecuado para:

Mtc1a01