FITTING IN THE UNIT (fig. 1 - pag. 1)
All installation operations must be performed by qualified personnel.
• The appliance can be fitted below the work top or in a column unit.
In both cases the dimensions specified in Table 1 must be observed.
• The oven is fitted in the unit as follows (fig. 1):
1. take out the screws A to remove the surround covers;
2. connect the oven to the electricity and gas supply and slide it into the unit;
3. secure the oven to the unit by means of 4 wood screws B;
4. refit the surround covers.
• Do not use the door as a lever when installing the oven.
• Do not exert pressure on the oven door when it is open.
CAUTION: do not obstruct cooling or fume discharge apertures or vents.
INSTALLATION PREMISES (fig. 2 - pag. 2)
For correct operation of the appliance, sufficient natural ventilation must be provided in the room
for combustion of the gas.
Installation personnel must follow the safety regulations in force in the country (UNI-CIG 7129
and 7131). The room must be ventilated directly via inlets on the outside walls (fig. 2).
These inlets must have a free section of at least 100 cm² (one or more inlets can be provided).
Combustion products must be discharged by means of extractor hoods connected to the flue or directly to the
outside (fig. 2).
If it is not possible to install an extractor hood, an electric fan must be fitted either to the outside wall or the
window; the room must be provided with ventilation inlets in compliance with current regulations. The fan flow
rate must be able to guarantee an hourly exchange of air 3-5 times the volume of the kitchen