Test data for PURITY C50 Quell ST
Substance
Guidelines
Chlorine
NSF/ANSI 42
* Test data for PURITY C150 Quell ST
Substance
Guidelines
Chlorine
NSF/ANSI 42
* Test data for PURITY C300 Quell ST
Substance
Guidelines
Chlorine
NSF/ANSI 42
Test data for PURITY C500 Quell ST
Substance
Guidelines
Chlorine
NSF/ANSI 42
** Test data for PURITY C1100 Quell ST
Substance
Guidelines
Chlorine
NSF/ANSI 42
* Values calculated on basis of the PURITY C50 Quell ST
** Values calculated on basis of the PURITY C500 Quell ST
Testing conditions
Flow rate PURITY C50 Quell ST:
Flow rate PURITY C500 Quell ST:
Pressure:
Temperature:
Capacity and flow rate table based on chlorine reduction
Water filter system
PURITY C50
Capacity
1900 Liters/
502 gallons
Rated service flow
0.25 gallons/min
(lpm)
6
Average
Maximum Effluent
Influent
Concentration
Concentration
2.1 mg/l
0.34 mg/l
Average
Maximum Effluent
Influent
Concentration
Concentration
2.1 mg/l
0.34 mg/l
Average
Maximum Effluent
Influent
Concentration
Concentration
2.1 mg/l
0.34 mg/l
Average
Maximum Effluent
Influent
Concentration
Concentration
2.1 mg/l
0.31 mg/l
Average
Maximum Effluent
Influent
Concentration
Concentration
2.1 mg/l
0.31 mg/l
0.25 GPM pH: 7.5 +/– 0.5
0.44 GPM pH: 7.5 +/– 0.5
60 +/– 3 psi
20 +/– 3 °C
PURITY C150
Quell ST
Quell ST
4766 Liters/
1259 gallons
0.25 gallons/min
Minimum
Average
Percent
Effluent
Removal
Concentration
83.6 %
0.21 mg/l
Minimum
Average
Percent
Effluent
Removal
Concentration
83.6 %
0.21 mg/l
Minimum
Average
Percent
Effluent
Removal
Concentration
83.6 %
0.21 mg/l
Minimum
Average
Percent
Effluent
Removal
Concentration
85.2 %
0.25 mg/l
Minimum
Average
Percent
Effluent
Removal
Concentration
85.2 %
0.25 mg/l
PURITY C300
PURITY C500
Quell ST
Quell ST
7917 Liters/
13458 Liters/
2091 gallons
3555 gallons
0.25 gallons/min
0.44 gallons/min
Average
Percent
Removal
91.4 %
Average
Percent
Removal
91.4 %
Average
Percent
Removal
91.4 %
Average
Percent
Removal
88.6 %
Average
Percent
Removal
88.6 %
PURITY C1100
Quell ST
22762 Liters/
6013 gallons
0.44 gallons/min