Installation Instructions

1. WINDOW REQUIREMENTS

• These instructions are for a standard
double-hung window. You will need to modify
them for other types of windows.
• The air conditioner can be installed without the
accordion panels if needed to fit in a narrow
window. See the window opening dimensions.
• All supporting parts must be secured to firm
wood, masonry or metal.
• The electrical outlet must be within reach of the
power cord.
(With accordion panels)
Model
AEW08
AEW10, AEW12
STORM WINDOW REQUIREMENTS
A storm window frame will not allow the air
conditioner to tilt toward the outside, and will keep
it from draining properly. To adjust for this, attach
a piece of wood to the sill.
WOOD PIECES
LENGTH: Long enough to fit inside the window
frame.
THICKNESS: To determine the thickness, place
than the top of the storm window frame or the vinyl
frame.
Attach securely with nails or screws provided by
the installer.
than storm
window frame
Storm window frame
49-7788
All manuals and user guides at all-guides.com
A
B
A
B
than vinyl frame
(on some windows)
Wood
Sill
Vinyl frame

PREPARE THE AIR CONDITIONER

A.
Hold the accordion panel in one hand and gently
pull back to free the open end.
B.
Slide the free end of the accordion panel into the
side panel rails. Slide the panel down. Be sure to
leave enough space to slip the top and bottom of
the frame into the rails on the cabinet.
NOTE: There is a right and a left accordion panel.
Be sure to use the proper panel for each side.
C.
Slide the left and right accordion panels into the
top and bottom mounting rails.
Top mounting rail
Top left
Bottom mounting rail
Top right
11