Delivery Content 1 x PoolLab 1.0 ® 1 x Light shield 3 x AAA Batteries 1 x Crushing | Stirring Rods 1 x 10ml syringe 1 x User guide 20 x Phenol Red Photometer tablets 20 x DPD N° 1 Photometer tablets 10 x DPD N°...
Switch On | Einschalten | Encender Allumer | Accendere 00:02 ZERO The On/Off button can also be used to skip countdown during measurement (not recommended). Die On/Off Taste kann auch zum Abbrechen des Countdowns während der Messung verwendet werden (nicht empfohlen). El botón de On/Off también se puede utilizar para cancelar la cuenta atrás durante la medición (no se recomienda).
Advices | Hinweise | Consejos Conseils | Consigli PHOTOMETER RAPID Always use PHOTOMETER grade tablets! Never use RAPID grade tablets! Do not touch reagent tablets! Immer PHOTOMETER-Tabletten und nie RAPID-Tabletten ver- wenden! Die Tabletten dürfen nicht berührt werden! ¡Usar siempre tabletas FOTÓMETRO y nunca usar tabletas RAPID! Las tabletas no se deben tocar! Toujours utiliser des pastilles de qualité...
Página 8
IMPORTANT | IMPORTANTE | WICHTIG Detergent waterproof (IP68 ) ZERO It is important to clean the device after each measurement to get rid of any reagent residues! Please ensure that the cuvette has been cleaned before each measurement (e.g. under clear water/or simply rinsing the cuvette in the pool is sufficient as long as no residues remain).
Página 9
È importante pulire il dispositivo dopo ogni misurazione per eliminare i residui di reagente! Assicurarsi che la cuvetta sia stata pulita prima di ogni misurazione (ad esempio sotto l'acqua chiara o semplicemente sciacquando la cuvetta nella piscina è sufficiente, purché non rimangano residui). Do not leave the device in the sun! Lassen Sie das Gerät nicht in der Sonne liegen! ¡No deje el dispositivo al sol!
Página 11
Tablet Mode: Press And Hold ZERO + Power Button ZERO ZERO ZERO Liquid Mode: Press And Hold ZERO + Power Button ZERO ZERO ZERO...
Página 12
From firmware version 72 onwards, you have the option of measuring the following parameters with tablets as well as with liquid reagents: pH, chlorine, chlorine dioxide, ozone and bromine. You can choose between two measurement settings in the unit: Tablets and liquid reagents. To ensure that the correct measurement result is displayed, check the current mode by pressing and holding ZERO &...
Página 13
A partire dalla versione 72 del firmware, avete la possibilità di misurare i seguenti parametri sia con pastiglie che con reagenti liquidi: pH, cloro, ossigeno attivo, biossido di cloro, ozono e bromo. È possibile scegliere tra due impostazioni di misurazione nell'unità: Compresse e reagenti liquidi.
QUICK START GUIDE Kurzanleitung Guía De Inicio Rápido Guide De Démarrage Rapide Guida Rapida Scan the QR-code to watch our intstruction video...
Página 15
Hold & Press To Switch On 3 x AAA 00:02 ZERO START: Take 10 ml Water Sample 10 ml No Reagents! waterproof (IP68 ) ZERO Put On Lightshield ZERO ZERO ZERO ZERO...
Página 16
Remove Lightshield Reagent(s) For Your Test (Refer To Chapter In Manual) ZERO ZERO Put On Lightshield Use Force! ZERO ZERO Completely Dissolved Residue Shortcut Await For Your Countdown Test (Refer To Chapter In Manual) ZERO ZERO...
Página 17
Quick Start Guide | Kurzanleitung | Guía De Inicio Rápido | Guide De Démarrage Rapide | Guida Rapida Empty & Clean For Next Test: Take 10ml waterproof (IP68 ) ZERO 10 ml *If Device Was Not Switched *If Device Was Switched Off, Off, Start From Step 8 Start From Step 3 Repeat...
ZERO waterproof (IP68 ) ZERO Take 10 ml Water Sample 10 ml No Reagents! waterproof (IP68 ) ZERO ZERO ZERO ZERO...
Página 19
Only 1 Time Per Test Batch | Nur Ein Mal Pro Testreihe Sólo Una Vez Por Lote De Prueba | Une Seule Fois Par Lot De Test | Solo Una Volta Per Test In Batch The "ZERO" step (page 18) is only necessary once after switching on. Make sure that the water to be measured does not (!) contain any tablet/reagent in the cuvette and that the light protection cover is in place.
Active Oxygen Aktivsauerstoff Oxígeno Activo Oxygène Actif Ossigeno Attivo (MPS) 0.0 – 30.0 ppm (mg/l) DPD N°4 Photometer* 10.0 30.0 *not part of standard equipment waterproof (IP68 ) ZERO Take 10 ml Water Sample waterproof (IP68 ) 10 ml ZERO...
Página 21
Active Oxygen | Aktivsauerstoff | Oxígeno Activo Oxygène Actif | Ossigeno Attivo 1 x DPD N°4 Use Force! Photometer* ZERO! (p.18) Completely Dissolved ZERO ZERO ZERO Residue ZERO ZERO...
Alkalinity Alkalinität Alcalinidad Alcalinité Alcalinità 0 – 200 ppm (mg/l) CaCO₃ Alkalinity–M Photometer waterproof (IP68 ) ZERO Take 10 ml Water Sample waterproof (IP68 ) 10 ml ZERO...
Página 23
Alkalinity | Alkalinität | Alcalinidad Alcalinité | Alcalinità Use Force! 1 x Alkalinity-M ZERO! (p.18) Photometer Completely Dissolved ZERO ZERO ZERO Residue ZERO ZERO...
Bromine Brom Bromo Brome Bromo 0.0 – 13.5 ppm (mg/l) DPD N°1 Photometer (DPD 1A + 1B Liquid) Glycine* 13.5 *not part of standard equipment waterproof (IP68 ) ZERO ZERO ZERO! Take 10 ml Water Sample (p.18) waterproof (IP68 ) 10 ml ZERO ZERO...
Página 25
Bromine | Brome | Bromo Brom | Bromo Only if your water sample does contain Chlorine next to Bromine (both disinfectants used), the following procedure "A" needs to be followed and Glycine* reagent needs to be used. Otherwise (only Bromine present), please follow procedure "B". Nur wenn die Wasserprobe neben Brom auch Chlor enthält (beide Desinfektionsmittel wurden benutzt), muss das Verfahren „A"...
Página 26
With Chlorine | Mit Chlor | Con Cloro Avec Du Chlore | Con il Cloro Glycine* Use Force! Completely dissolved ZERO ZERO Residue Tablet Or Liquid? (p. 10) DPD N°1 Photometer Use Force! DPD 1A + DPD 1B Completely dissolved ZERO ZERO Residue...
Página 27
Bromine | Brom | Bromo | Brome | Bromo Without Chlorine | Ohne Chlor Sin Cloro | Sans Chlore | Senza Cloro Tablet Or Liquid? (p. 10) DPD N°1 Photometer DPD 1A + Use Force! DPD 1B Completely Dissolved ZERO ZERO Residue 8 /6...
Calcium Hardness Kalziumhärte Dureza De Calcio Dureté Calcique Durezza Del Calcio 0 – 500 ppm (mg/l) POL20CaH1* POL20CaH2* *not part of standard equipment waterproof (IP68 ) ZERO ZERO ZERO! Take 10 ml Water Sample (p.18) waterproof (IP68 ) 10 ml ZERO ZERO...
Página 29
POL20CaH1* POL20CaH2* *Shake Before Use! 10 x 10 x ZERO ZERO ZERO ZERO...
Página 30
Calcium Hard. | Kalziumhärte | Dureza De Calcio | Dureté Calcique | Durezza Del Calcio ZERO ZERO ZERO ZERO...
Chlorine Chlor Cloro Chlore Cloro 0.00 – 8.00 ppm (mg/l) DPD N°1 Photometer (DPD 1A + 1B Liquid) DPD N°3 Photometer (DPD 3C Liquid) 0.00 4.00 8.00 waterproof (IP68 ) ZERO Take 10 ml Water Sample waterproof (IP68 ) 10 ml ZERO...
Página 33
Tablet Or Liquid? (p. 10) DPD N°1 Photometer DPD 1A + ZERO! (p.18) DPD 1B ZERO ZERO Use Force! Completely Dissolved ZERO ZERO Residue...
Página 34
Tablet Or Liquid? (p. 10) DPD N°3 Photometer DPD 3C ZERO ZERO ppm = mg/l Use force! Completely Dissolved ZERO ZERO Residue...
Página 35
Free Chlorine | Freies Chlor Cloro Libre | Chlore Libre | Cloro Libero ZERO Total Chlorine is measured directly after free Chlorine without emptying the cuvette. The DPD 3 tablet is added to the sample water which already contains the DPD 1 tablet (dissolved). Combined Chlorine is calculated as Total Chlorine minus free Chlorine.
Página 36
El cloro total se mide directamente después de cloro libre, sin necesidad de vaciar la cubeta. La tableta DPD 3 se añade a la cubeta en la que la tableta DPD 1 ya está disuelta. El cloro combinado se calcula a partir de cloro total menos cloro libre.
Chlorine Dioxide Chlordioxid Dióxido De Cloro Dioxyde De Chlore Biossido Di Cloro 0.00 – 11.40 ppm (mg/l) DPD N°1 Photometer (DPD 1A + 1B Liquid) Glycine* 0.00 5.00 11.40 *not part of standard equipment waterproof (IP68 ) ZERO ZERO Take 10 ml Water Sample ZERO! (p.18) waterproof...
Página 39
Only if your water sample does contain Chlorine next to Chlorine Dioxide (both disinfectants used), the following procedure "A" needs to be followed and Glycine* reagent needs to be used. Otherwise (only Chlorine Dioxide present), please follow procedure "B". Nur wenn die Wasserprobe neben Chlordioxid auch Chlor enthält (beide Desinfektionsmittel wurden benutzt), muss das Verfahren „A"...
Página 40
With Chlorine | Mit Chlor Con Cloro | Avec Du Chlore | Con il Cloro Glycine* Use Force! Completely Dissolved ZERO ZERO Residue Tablet Or Liquid? (p. 10) DPD N°1 Photometer Use Force! DPD 1A + DPD 1B Completely Dissolved ZERO ZERO Residue...
Página 41
Cl. Dioxide | Chlordioxid | Dióxido De Cl. Dioxyde De Cl. | Biossido Di Cl. Without Chlorine | Ohne Chlor Sin Cloro | Sans Chlore | Senza Cloro Tablet Or Liquid? (p. 10) DPD N°1 Photometer Use Force! DPD 1A + DPD 1B Completely Dissolved...
Cyanuric Acid Cyanursäure Ácido Cianúrico Acide Nurique Acido Cianurico 0 – 160 ppm (mg/l) CYA–Test Photometer waterproof (IP68 ) ZERO ZERO ZERO! Take 10 ml Water Sample (p.18) waterproof (IP68 ) 10 ml ZERO ZERO...
Página 43
1 x CYA–Test Use Force! Photometer Completely Dissolved ZERO ZERO Residue ZERO ZERO...
Hydrogen Peroxide Wasserstoffperoxid Peróxido De Hidrógeno Peroxyde D'Hydrogène Perossido Di Idrogeno (LR) 0.00 – 2.90 ppm (mg/l) Hydr. Peroxide LR Photometer* 0.00 1.45 2.90 *not part of standard equipment waterproof (IP68 ) ZERO ZERO ZERO! Take 10 ml Water Sample (p.18) waterproof (IP68 )
Página 45
1 x Hydr. Peroxide Use force! Photometer* completely dissolved ZERO ZERO residue ZERO ZERO...
Página 46
Hydrogen Peroxide Wasserstoffperoxid Peróxido De Hidrógeno Peroxyde D'Hydrogène Perossido Di Idrogeno (HR) 0 – 200 ppm (mg/l) Hydr. Peroxide HR Photometer* Acidifying PT *not part of standard equipment waterproof (IP68 ) ZERO ZERO Take 10 ml Water Sample ZERO! (p.18) waterproof (IP68 ) 10 ml...
Página 47
1 x Acidifying Use Force! ZERO ZERO Completely Residue Dissolved 1 x Hydr. Peroxide Photometer* Use Force! ZERO ZERO Completely Residue Dissolved ZERO ZERO...
Ozone Ozon Ozono 0.00 – 4.00 ppm (mg/l) DPD N°1 Photometer (DPD 1A + 1B Liquid) DPD N°3 Photometer (DPD 3C Liquid) Glycine* 0.00 2.00 4.00 *not part of standard equipment waterproof (IP68 ) ZERO ZERO Take 10 ml Water Sample ZERO! (p.18) waterproof...
Página 49
Only if your water sample does contain Ozone next to Chlorine (both disinfectants used), the following procedure "B" needs to be followed and Glycine* reagent needs to be used. Otherwise (only Ozone present), please follow procedure "A". Nur wenn die Wasserprobe neben Ozon auch Chlor enthält (beide Desinfektionsmittel wurden benutzt), muss das Verfahren „B"...
Página 50
Without Chlorine | Ohne Chlor Sin Cloro | Sans Chlore | Senza Cloro Tablet Or Liquid? (p. 10) DPD N°1 + DPD N°3 Use Force! Photometer DPD 1A + DPD 1B + DPD 3C Completely Dissolved ZERO ZERO Residue ZERO ZERO...
Página 51
Ozone | Ozon | Ozono With Chlorine | Mit Chlor Con Cloro | Avec Du Chlore | Con il Cloro Tablet Or Liquid? (p. 10) DPD N°1 + DPD N°3 Use Force! Photometer DPD 1A + DPD 1B + Completely DPD 3C Dissolved ZERO...
Página 52
With Chlorine | Avec Du Chlore Con Cloro | Mit Chlor | Con il Cloro 0 ml ZERO 10 ml waterproof (IP68 ) ZERO Glycine* Use Force! Completely Dissolved ZERO ZERO Residue...
Página 53
Ozone | Ozon | Ozono With Chlorine | Avec Du Chlore Con Cloro | Mit Chlor | Con il Cloro Tablet Or Liquid? (p. 10) DPD N°1 + DPD N°3 Use Force! Photometer DPD 1A + DPD 1B + Completely DPD 3C Dissolved ZERO...
6.50 – 8.40 pH Phenol Red Photometer (Phenol Red Liquid) waterproof (IP68 ) ZERO Take 10 ml Water Sample waterproof (IP68 ) 10 ml ZERO...
Página 55
Tablet Or Liquid? (p. 10) Phenol Red Photometer ZERO! (p.18) Phenol ZERO ZERO Use Force! Completely Dissolved ZERO ZERO Residue...
Página 56
ZERO The Total Alkalinity value has to be minimum 50 mg/l to obtain a correct pH value. La valeur totale de l'alcalinité doit être au minimum de 50 mg/l pour obtenir une valeur de pH correcte. El valor de alcalinidad debe ser superior a 50 mg/l para obtener un pH correcto.
PHMB 5 – 60 ppm (mg/l) PHMB Photometer* *not part of standard equipment waterproof (IP68 ) ZERO ZERO ZERO! Take 10 ml Water Sample (p.18) waterproof (IP68 ) 10 ml ZERO ZERO...
Página 59
PHMB 1 x PHMB Photometer Use Force! Completely Dissolved ZERO ZERO Residue ZERO ZERO...
Página 60
It is imperative that you clean the objects used for the measure- ment and come into contact with the sample water containing the reagent (cuvette, lid, stirring rod) thoroughly with a brush, water and then with distilled water, otherwise the measuring equipment may turn blue over time.
Total Hardness Gesamthärte Dureza Total Dureté Totale Durezza Totale 0 – 500 ppm (mg/l) POL20TH1* POL10TH2* *not part of standard equipment waterproof (IP68 ) ZERO ZERO Take 10 ml Water Sample ZERO! (p.18) waterproof (IP68 ) 10 ml ZERO ZERO...
Página 63
POL20TH1* POL10TH2* *Shake Before Use! 10 x ZERO ZERO ZERO ZERO...
Urea Harnstoff Urée 0.1 – 2.5 ppm (mg/l) Dechlor* PL Urea PL Urea Ammonia N°1 Ammonia N° *not part of standard equipment waterproof (IP68 ) ZERO ZERO Take 10 ml Water Sample ZERO! (p.18) waterproof (IP68 ) 10 ml ZERO ZERO...
Página 65
1 x Dechlor ZERO ZERO Use Force! ZERO ZERO Completely Dissolved Residue PL Urea *Shake Before Use! ZERO ZERO...
Página 66
PL Urea *Shake Before Use! ZERO ZERO ZERO ZERO...
Página 67
Urea | Harnstoff | Urée 4 14 Ammonia N°1 ZERO ZERO Ammonia N°2 ZERO ZERO...
Página 68
ZERO ZERO If the sample contains free chlorine, a „Dechlor“ tablet has to be added to the vial, before adding PL Urea 1 and PL Urea 2. Ammonia N° 1 only dissolves entirely after Ammonia N° 2 was added. Ammonia and chloramines will be detected together. The result displayed will show the sum of both.
Página 69
Urea | Urée | Harnstoff Si la muestra contiene cloro libre, hay que añadir una pastilla de "Dechlor" al vial, antes de añadir PL Urea 1 y PL Urea 2. Ammonia N°1 no se disuelve por completo hasta que agregue Ammonia Nº 2. El amoníaco y cloraminas se detectan juntos.
OR-UR (Dilution) | OR-UR (Verdünnung) OR-UR (Dilución) | OR-UR (Diluzione) OR = Overrange / UR = underrange. Test result is outside the range of the method. OR results can be brought into measurement range by dilution. Use syringe to take only 5ml (or 1ml) sample water plus 5ml (9ml) distilled water.
Troubleshoot | Fehlerbehebung | Soluc. Problemas | Dépannage | Risoluzione Die Problemi 1) 01.01.1970: The date on the PoolLab 1.0 is set to 01.01.1970 when ® delivered, after each battery change and after each update. Please reconnect to the LabCOM app so that the smartphone date is adopted again.
Página 73
1) 01.01.1970: la date du PoolLab 1.0 est réglée sur le 01.01.1970 à la ® livraison, après chaque changement de batterie et après chaque mise à jour. Veuillez vous reconnecter avec l'application LabCOM pour que la date du smartphone soit à nouveau adoptée. 2) Valeurs idéales: Veuillez contacter le fournisseur de la chimie de...
Página 74
Changing The Cuvette | Küvettenwechsel | Cambiar La Cubeta | Changer La Cuvette | Cambiando La Cuvetta 90° ZERO ZERO 90° ZERO ZERO...
Technical Data | Technische Daten | Datos Técnicos | Données Techniques | Dati Tecnici www.poollab.org MSDS msds.water-id.com Cloud labcom.cloud 530 nm / 570 nm / 620 nm LED: 3 x AAA (1.5 V, LR03) 300 sec. ï 5 - 45°C IP 68 (1 h / 1.2 m) Developed in Germany Produced in PRC...
D-76344 Eggenstein-Leopoldshafen Federal Republic of Germany represented by the general manger Dipl. Ec. Andreas Hock here- with declares as follows: The product “PoolLab 1.0" complies with the requirements of ® the following standards for: ETSI EN 300 328 (V2.2.2) EN 62479 (2010) ETSI EN 301 489-1 (V2.2.3)
Página 84
UKCA Complaince Statement UK Conformity Assessed We, Water-i.d. GmbH Germany, hereby certify our responsibility, that the following product: PrimeLab 2.0 Photometer, is tested to and conforms with the essential test suites included in the following standards, which are in force within the UK: Standards Legislation Number Regulations 2016 (S.I.
Página 85
FCC Part 15 Compliance Statement IC Licence-Exempt RSS Compliance Statement This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Página 86
(1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. This device complies with Industry Canada's RSS for licence-exempt radio equipment. Operation is permitted under the following two conditions: (1) this device may not cause interference, and (2) the user of this device must accept any radio interference received, even if the interference is likely to affect the operation of the device.
Certificate | Zertifikat | Certificado Certificat | Certificato Certificate Of Compliance We hereby certify that the device PoolLab 1.0 ® With it‘s serial number as stated below, has passed intensive visual and technical checks as part of our QM documentation. We confirm the device got factory-calibrated.