TAZ-4H ADD-A-ZONE PANEL

CONFIGURATION

To Enter Configuration
1. Press the Mode button once (the Config LED will light
up).
2. Use the Back and Next buttons to navigate through the
configuration settings. Scroll through the selection
choices by using the "Adjust Setting" Left and Right
arrow buttons. Pressing Next enters the selected
option for that menu item and advances to the next
menu.
3. The flow chart below illustrates TAZ-4H zone panel
configuration.
Which Zones is this TAZ-4H controlling? Since the HZ432 is controlling zones 1-4, options are:
ZONES CONTROLLED
[5-8], [9-12], [13-16], [17-20], [21-24], [25-28], [29-32]
[5-8] ->
ZONE 5-A TSTAT
What type of thermostat is controlling each zone?
[CONV] ->
Options are: [CONV], [HTPUMP-O], [HTPUMP-B], [NOT CONNCTD].
"HTPUMP-O" would be a heat pump thermostat configured to energize the reversing valve in
ZONE 6-B TSTAT
cooling.
[CONV] ->
There is a letter after the zone number because the lights, and thermostat/damper wiring
ZONE 7-C TSTAT
connections are labeled Zone A-D. This is because a TAZ-4H panel could be configured to
[CONV] ->
control zones 5-8, 6-9, etc.
When you are in checkout, the first zone that the panel controls will have an A. This could be 5A,
ZONE 8-D TSTAT
9A, 13A, depending on how many TAZ-4H panels are used.
[CONV] ->
LCD CONTRAST
Options are: [1]-[10]
<- [5] ->
SAVE CHANGES?
Make sure you select "YES" using the arrow button before pressing the NEXT button.
[NO] YES
M38627

HOME MODE

The display at home mode will either indicate communication
is good or at least one zone is failing to communicate to the
HZ432 zone panel. The TAZ-4H panel is factory configured
for zones 5-8 with conventional thermostats, so it will
indicate communication status as soon as it is powered even
if it has not been configured.
33-00578EFS—01
HOME
CONFIG
CHECK OUT
BACK
ADJUST SETTING
Fig. 13.
HOME
CONFIG
CHECK OUT
ZONES 5-8
COMM OK
BACK
ADJUST SETTING
10
HOME
CONFIG
CHECK OUT
MODE
NEXT
BACK
ADJUST SETTING
Fig. 12.
ZONES 5-8
COMMUNICATION
MODE
OK
COMM OK
COMMUNICATION
ZONES 5-8
NEXT
ISSUE FROM
COMM ERROR
TAZ-4H TO HZ432
Fig. 14.
MODE
NEXT
M38626
M38628