or removal of any allegedly defective part. This
warranty gives you specific legal rights and
you may also have other rights, which vary,
from state to state.
REPLACEMENT PLUS
™
PROTECTION
The product to which this warranty applies is
covered by Replacement Plus protection for a
period of two (2) years, provided that the prod-
uct has been installed in strict accordance with
written installation instructions and in accord-
ance with all local codes and standards,
including those pertaining to fire-rated con-
struction. Under this warranty feature, Air Vent,
Inc., at no charge, will replace any part cov-
ered by this warranty and found to be defective
during the Replacement Plus period (The
Replacement Plus period begins when the
whole house attic fan installation is complet-
ed). Maximum liability under Replacement Plus
will be equal to the reasonable cost of the re-
placement part, including labor to remove the
defective part and install the replacement part.
In instances in which Air Vent, Inc., according
to the terms of this warranty has agreed to pay
the cost of labor required to replace a defective
part, Air Vent, Inc. will provide reimbursement
only upon receipt of a copy of the contractor's
invoice or other written evidence of the com-
pletion of the work which Air Vent, Inc., at its
sole discretion, deems acceptable.
OPERATING INSTRUCTIONS
To start the unit, press "START." The fan will
•
resume the speed setting that was last selec-
ted as indicated by the corresponding LED
which lights up momentarily when the
"START" button is depressed.
Note:
Upon startup, it will take approximately
15 seconds (time for shutter to completely
open) before the processor is capable of
accepting signals from the remote control
transmitter.
WHSP2000 SPECIFICATIONS
General Electrical Ratings
115 VAC 60 Hz
Startup Current
Approx. 4.0 A
R-Value of Shutter
R-25
Weight
25 lbs. (without grill)
Remote Batteries
(2) 1.5 V – AA (Alkaline Recommended) NOT INCLUDED
Airflow (CFM @ 0.0" S.P.)
1290
Current Draw (A)
2.0
Power Consumption (W)
220
Fan Speed (RPM)
1665
To change speeds, press the "START" button
•
until the desired speed is selected as indi-
cated by the corresponding LED on the
remote control.
Remember:
It will only be possible to change
speeds after the shutter (inside of the attic)
has reached the fully open position.
To use the timer feature, depress the "SET
•
RUN HOURS" button until the desired run
time is selected as indicated by the corre-
sponding LED which lights up momentarily
when the button is depressed. When the unit
is turned off and then back on, the timer fea-
ture defaults to manual mode.
Note:
The unit must be running and the shut-
ter must be fully open before the timer fea-
ture can be activated.
To stop the unit at any time, depress the
•
"STOP" button. This interrupts power to the
fan motors and sends power to the shutter
drive motor. It will take approximately 15
seconds for the shutter to completely close
and for the processor to recognize signal
transmission from the remote control.
In order to conserve battery power, an 8-sec-
•
ond timeout feature has been integrated into
the remote control software. After 8 seconds
has elapsed from the last signal transmis-
sion, any subsequent signal transmitted (by
depressing either the "START" button to
change speeds or the "SET RUN HOURS" but-
ton to change the timer selection) will be a
duplicate of the current setting. The button
used to activate the desired setting change
will need to be depressed consecutive times
until the corresponding LED of the desired
setting momentarily lights up.
1410
1600
1700
2.1
2.3
2.4
240
270
290
1835
2040
2215
4
WHSP2000
Troubleshooting Guide
2200
3.1
370
2830