installation
4. HOLD THE PIPE, remove pipe
clamp and slide well seal over
rigid PVC pipe and onto well
casing. Position assembly
so that twelve inches of rigid
PVC pipe protrude from well
seal. Alternately turn bolts
on well seal clockwise until
rubber gaskets are tight
against well casing and rigid
PVC pipe.
5. Cement 1-1/2" PVC elbow onto
rigid PVC pipe protruding from
well seal. If desired, some length
may be cut off of rigid PVC pipe
before cementing elbow. Use a
round file or knife to smooth the
inside of any rigid PVC pipe that
has been cut.
6. Thread a 1-1/2" male PVC
adapter into the front of pump.
Hand tighten, then turn 1/4 turn
with wrench.
7. Cement
as many
sections and
couplings
of PVC pipe
needed to
connect the
PVC elbow to the 1-1/2" male PVC adapter in the front of
the pump.
8. Using pipe wrench, thread 1-1/2"
discharge tee into top of pump.
Remove 1-1/2" plug from top
of discharge tee. Put a garden
hose into top of discharge tee.
Fill pipes and pump until water
overflows from top of discharge
tee. This may take several
minutes.
9. Thread the 1-1/2" pipe plug back
into the top of discharge tee.
10. Complete all electrical connections as specified on page 2 in
the pre-installation instructions.
For parts or assistance, call Master Plumber Customer Service at 1-800-628-9439
APPROX.12"
OF PVC PIPE
PROTRUDING
FROM WELL SEAL
1-1/2"
WELL SEAL
7083 0716
1-1/2"
PVC
ELBOW
TOP OF
PVC PIPE
PROTRUDING
FROM WELL
SEAL
7084 0716
PUMP
1-1/2"
MALE PVC
ADAPTER
7085 0716
1-1/2" PVC PIPE
7086 0716
DISCHARGE
TEE
7087 0716
1-1/2"
PIPE
PLUG
7088 0716
11. Place a large bucket beneath
discharge tee outlet. Start
motor. If pump is offset from
well 4 feet or more, it may take a
few minutes for pump to prime.
Failure to prime in 5 minutes:
Stop motor, remove 1-1/2" plug
from discharge tee, add more
water, try again.
12. Allow pump to run long enough
to clear well of sediment and
to insure well will not run dry.
Stop motor. Thread 1-1/2" make
PVC adapter into discharge tee
outlet.
13. Cement as many PVC pipe sections and couplings needed
to connect the 1-1/2" male PVC adapter to inground
sprinkler system. Complete installation should look like
the figure below.