NOTE: In areas with hard water, reverse polarity systems may require occasional
manual cleaning
Life of EcoSalt electrolytic cells vary substantially from one installation to another due to
variations in operating time, water quality and composition, system and cell
maintenance. Please ensure that when cell replacement is necessary you use the
correct genuine EcoSalt replacement cell to match your system. The correct EcoSalt
Replacement cells to use are shown in the table below:
EcoSalt: Reverse Polarity Replacement Cells
Model
M0808
MES13
MES20
MES26
To clean the EcoSalt Cell
and removed from the pool return line by undoing the unions. Take care not to lose the
o-rings and always make sure that the Power Supply is turned off
METHOD 1
Add 1 part HYDROCHLORIC ACID to 5 parts WATER in a suitable container. The Cell
should be placed on a surface that allows it to form a U shape and some of the solution
can be poured into the up-turned cell. Take care when doing this as the solution can
foam and create a spill which must be cleaned up by dilution. As an alternative the Cell
can be immersed completely in a container. When clean the Cell should be rinsed
thoroughly and the connection should be dried carefully to avoid connector corrosion. It
should not take longer than a few minutes to clean, if it does the Cell should be cleaned
more frequently. Return the Cell to its position and re-connect it.
METHOD 2
As an alternative, an approved commercial Cell cleaning solution can be used a number
of times effectively.
SAFETY DEVICE:
Page 10 of 100
Type / Output
EcoSalt 8 g/h
EcoSalt 13 g/h
EcoSalt 20 g/h
EcoSalt 26 g/h
it should be disconnected from the Power Supply Unit
Cell Model
M0685
M0681
M0682
M0683
P/N MMAN001FRA-3