LED 1
LED 2
Alarm/Fault
(UV Controller
(UV Lamp
Condition
Status)
Status)
UV Lamp Ignition/Run
Red
Flashing Red
Fault
UV Lamp Near End of
Green
Yellow
Life Warning
UV Lamp At End of Life
Green
Flashing Red
Fault
UV Lamp EOL
Green
Flashing Red
Exceeded Fault
AC Voltage out of
Flashing Red
Flashing Red
Range
UV Controller Fault
Flashing Red
Red
Section 6
Troubleshooting
Symptom
Possible Cause
GFCI and/or breaker tripped
No power
Transient voltage surge suppressor (TVSS) damaged
Controller damaged
Connection between lamp and lamp plug is wet
GFCI or breaker repeatedly
trips
Short-circuit in the electrical assembly
Leak at inlet or outlet
Threaded pipe fittings are leaking
Condensation of moist air on cold chamber (slow
accumulation)
Leak detected from area of UV
O-ring damaged, deteriorated or incorrectly installed
chamber
Lamp/sleeve assembly not properly installed (too tight or not
tight enough)
Alarm
Refer to
Section
5.
Equipment downstream of UV system is acting as a breeding
ground for pathogens
System is operating but water
tests reveal bacterial
Pathogens are residing in the distribution lines post-UV
contamination
Recontamination from pipe dead-ends
Unit is unplugged.
No power at AC power outlet
Lamp timer does not read
anything
Power cord is damaged
Power surge caused damage to electrical assembly
Indicator Lights
Audio Indicator
Notes
Status
1. Unplug UV system from main power supply.
2. Check for secure lamp connection.
3. Restore power to UV system.
Beeping
4. If failure message repeats, replace UV lamp.
Audible alarm may be silenced for 24 Hours.
Off
Warning: Lamp will require replacement shortly.
1. Follow instructions in manual to replace lamp.
Chirp
Warning Chirp may be silenced for 7 Days.
1. Follow instructions in manual to replace lamp.
Chirp
Warning Chirp may be silenced for 24 Hours.
When the AC voltage is back in range (>93V or <265V) the
Beeping
alarm cancels and normal operation is resumed.
Audible alarm may be silenced temporarily.
1. Unplug UV system from main power supply.
2. Allow 30 seconds for unit to fully power down.
3. Restore power to UV system.
Beeping
4. If failure message repeats, replace controller.
Audible alarm may be silenced for 24 Hours.
Possible Solution
Reset GFCI and/or breaker
Replace TVSS
Replace controller and use a TVSS
Clean and dry lamp pins and lamp plug, check unit for leaks
or condensation
Replace controller
Clean threads, reseal with Teflon tape and retighten
Control humidity or relocate unit
Inspect and replace if deteriorated
Tighten assembly hand-tight
Refer to
Section
5.
Ensure UV is the last piece of treatment equipment
Ensure all distribution lines have been disinfected with
chlorine. Refer to
Section
3.2.
Remove any pipe dead-ends and flush with chlorine. Refer to
Section
3.2.
Plug unit into AC power outlet
Replace fuse or reset breaker
Replace power cord
Replace controller and use a surge protector (TVSS)
Troubleshooting
Información general
Sección 2
Elemento
1
Cámara UV (incluye abrazaderas de cámara y abrazadera de anillo)
2
Vaina tubular (incluye juntas tóricas)
3
Junta tórica
4
Lámpara (incluye juntas tóricas)
5
Perno de la vaina tubular
6
Abrazadera de montaje del controlador
7
Ficha de referencia
8
Controlador (incluye abrazadera de montaje del controlador, ficha de referencia)
9
Conector de lámpara
10
Cable de alimentación (120 V)
12
33
Información general
5
6
4
3
2
1
10
Figura 1 Componentes del sistema
Descripción
7
8
9
N.º pieza
-
602732
-
602805
602665
-
-
650733R-003
-
602636