12. QUICK VIEW OF BASIC SETTINGS

From the main screen, where the current time and date are indicated, with a press on the
+ button we can quickly view some basic settings of the device configuration, such as the
software version, the operating hours of the pumps, if a pump is running, etc ...
13. WARNING MANAGEMENT
One of the main premises of the device is to try to minimize the interruption of the hydraulic
supply as much as possible. For this, there is an auto reset system that, in case of reading
the motor consumption outside the established values, both due to excess consumption (over
consumption) and by default (dry work) allows the reactivation of the system after a few
minutes, without requiring the intervention of the installer.
The system will initially stop the affected pump for a period of 5 minutes. After this time, it
will re-enable it so that it can function normally again. If a fault occurs again, this time it will
stop the pump for 10 minutes, re-enabling it normally after this time. This auto-reset loop with
increased time will occur until the system understands that there is a non-temporary problem
in the pump or the installation that will prevent the pump from working. In this case, the pump
will remain disabled indefinitely until the direct intervention of the installer.

14. ALARMS

MESSAGE
TRANSDUCER FAILURE
TANK OVERFILLED
AUTOMATIC STOP
26
CAUSE
The pressure transducer
is missing, damaged, or
not wired correctly.
Digital input 4 has
been activated.
Digital input 1 has been
activated.
SOLUTION
Check that the transducer is
connected with the correct polarity
to the specific input for the pressure
transducer. If the error message
persists, it may mean that the
transducer is defective and must be
replaced.
In a dirty water lifting system, it
indicates that the level float in charge
of indicating the over-level of the
tank is active, therefore there is a
danger of overflow.
In a tank-fill booster system, it
indicates that the target tank is about
to overflow.
This message will only be displayed
on a pressure switch or pressure
transducer starting system, and
indicates that the water supply tank
for the pumps is exhausted.