It appears during performance of
PATIENT
the ETF testing for non-perfora-
ted eardrums
PROBE NOT
It appears during middle ear
CONNECTED
analyzer testing, if the probe is
not connected up to the device
AUTORUN
It appears when middle ear
CHECK
analyzer tests are performed
when the Autorun function has
been activated
DO YOU
This query appears after entry of
CONFIRM ?
plot cancellation or parameter
change requests
CHANGE
This message appears at the end
CALIBRATION
of the device calibration proce-
DATE ?
dure, once the "SAVE" softkey has
been pressed and values have
been changed.
INSERT PROBE
This message appears when on
INTO THE
the Compliance Calibration page
SPECIFIED CAVITY
PRESS
This message comes up on the
CONFIRM/AUTO-
Compliance Calibration page
MATIC
the instant in which the probe is
KEY
inserted into the specified cavity
CHECK CAVITY
This message is given on the
Compliance Calibration page if
the probe is not inserted into the
displayed cavity
READ
This message is given on the
VALUE (ml)
Compliance Calibration page, at
the end of the calibration process
INSERT PROBE
This message appears on the
INTO THE 2cc
ARLT Calibration page, if the
CAVITY
probe is not inserted into the
2cc cavity.
PRESS RUN TO
This message appears on the
PERFORM
ARLT Calibration page, when
CALIBRATION
the probe is inserted into the
2cc cavity
System
It means that the
message
patient is required
to swallow, when
instructed by the
operator to do so
Error
It means that the probe
message
is not hooked up to the
appropriate connector
on the device's rear
panel
System
It means that the test is
message
being performed with
the Autorun function
activated
System
It means that a plot
message
cancellation or a para-
meter change request
has been entered
System
It provides the option
message
of updating periodic
calibration dates
System
This message refers to
message
the cavity value displa-
yed on the Calibration
page, that it is necessa-
ry to insert the probe
into for calibration
performance
System
it provides instructions
message
that need to be follo-
wed in order to pro-
ceed with compliance
calibration
System
It means that the probe
message
has been inserted into
the wrong cavity
System
It means that the value
message
that is displayed is the
real-time value reading
by the device
System
You are instructed to
message
insert the probe into
the 2cc cavity in order
to perform calibration
System
It provides instructions
message
on proceeding with
calibration
No action is required
Connect the probe up
to the correct rear-panel
connector
No action is required - if
the Autorun function
is not wanted, it can be
deactivated via the Setup
menu
Press either the YES or
the NO when the query
appears
Press either the YES or
the NO when the query
appears
Insert the probe into the
test cavity as displayed
Press the confirmation
key to calibrate selected
probe tone frequency
or automatic key to
calibrate all probe tone
frequencies (PT models)
Proceed with inserting
the probe into the
correct test cavity, as
displayed
No action is required
Proceed with inserting
the probe into the 2cc
cavity
Press the Start key as
instructed
43