QH-104263.3
ASSEMBLY AND ELECTRIC CONNECTION
Remove both safety elements on the front grid, used as transport protection.
The quartz heater must be installed in a horizontal position only. Do not install at the ceiling or
vertically. During installation respect the minimum distances indicated in Fig. 1.
Find the most appropriate position so as not to block access to the pull switch cord and the switch, at
all times respecting the safety distances indicated in Fig. 1. Mark the holes for mounting on the wall
where the heater is to be installed: 80 mm for the horizontal position and 105 mm for the vertical
position. Fix the quartz heater with the attached dowel screws to the wall.
After assembly and electric installation on the wall the upper part can be swivelled to an angle of max.
55°.
Arrange a convenient angle for the device and fix the mechanism by tightening both lateral screws (Fig.
2).
Now you can use the quartz heater.
Note:
The heater must not be mounted less than 1800mm above the floor, less than 700mm under the ceiling,
less than 500mm away from side wall(s).
Fig. 1
Fig. 2
CLEANING
Let the quartz heater cool down and clean it only with dry cloth. Do not touch the quartz tubes with
your fingers!
Never use water and never touch the heater with wet hands.
TECHNICAL DATA
Operating voltage: 220-240V ~ 50/60Hz
Power consumption: 1200W