Pull out the fleece filter bag on the
flange towards the top.
Tightly close the fleece filter bag with
lock cap.
Dispose of the fleece filter bag accord-
ing to the local provisions.
Insert the new fleece filter bag.
Insert and lock the suction head.
Replace the disposal bag
Illustration
Release and remove the suction head.
Put the disposal bag over.
Pull the opening of the disposal bag out
toward the back over the suction sup-
port.
Tightly close the disposal bag with ca-
ble tie underneath the opening.
Remove disposal bag.
Dispose of the disposal bag according
to the local provisions.
Attach the new disposal bag.
Pull disposal bag over the container.
Insert and lock the suction head.
Clean/replace the cooling air filter
Illustration
Allow device to cool down.
Release the cooling air flaps with
screwdriver and swivel them out.
Clean (vacuum, wash) or replace the
cooling air filter.
Fold in the cooling air flaps and snap
them in place.
Cleaning the electrodes
Release and remove the suction head.
Clean the electrodes with a brush.
Insert and lock the suction head.
Troubleshooting
DANGER
First pull out the plug from the mains before
carrying out any tasks on the machine.
Note: In case of a failure (e.g. filter break-
age) the appliance must be turned off im-
mediately. The failure must be remedied
before the appliance is put into operation
again.
22
Suction turbine does not run
Check the receptacle and the fuse of
the power supply.
Check the power cable, the power plug,
the electrodes and the receptacle of the
device.
Turn on the appliance.
Suction turbine turns off
Empty the container.
Insert flat folded filter.
Suction turbine does not start again
after the container has been
Turn off the appliance and wait for 5
seconds, turn it on again after 5 sec-
onds.
Clean the electrodes as well as the
space between the electrodes with a
brush.
Suction capacity decreases
Remove blockages in the suction noz-
zle, suction tube, suction hose, or flat
pleated filter.
Replacing the full fleece filter bag.
Replace the filled disposal bag
Ensure the filter cover properly locks
into place.
Replace the flat pleated filter.
Dust comes out while vacuuming
Illustration
Check/correct the correct positioning of
the flat pleated filter.
Replace the flat pleated filter.
Automatic shut-off (wet vacuum
cleaning) does not react
Clean the electrodes as well as the
space between the electrodes with a
brush.
Continuously check the filling level in
case of non-conductive liquid.
– 7
EN
emptied