PUMP PRIMING (Pr)
Pump priming feature begins at start-up. When your spa is energized, the LCD
window displays a "Pr" message. This mode lasts approximately four to five
minutes, if not exited manually by pressing the TEMP+ pad.
UNDERWATER LIGHTS
Press the LIGHT pad on bather's panel to turn the underwater lights on and off.
The low-voltage system produces a night light for evening use. After being on
for 60 minutes, the lights automatically turn off. For Aqua Ambiance and
Constellation use SPA LIGHT pad. Step one: turn on light. Step two: turn off and
then on within 2-3 seconds to change color.
NOTE: LED lights do not qualify for labor coverage. These parts can be
purchased or exchanged under warranty at your authorized Marquis Spas®
dealer.
WATERFALL FEATURE
The water flow is controlled by an independent valve.
JETS 1 (One Pump Models)
Use the JETS 1 pad on the bather's panel control. First press of the JETS 1 pad
activates pump on low-speed (and starts soak timer). Second press of the JETS
1 pad activates pump on high-speed. Third press of the JETS 1 pad turns jets
off for Quiet Soak mode. If the system is in a filter cycle or calling for heat, low
speed will continue to run. The high and low speed operation will stop after 15
minutes of use. To restart the pump, press the JETS 1 pad. The yellow LED
indictor by the JETS 1 pad will illuminate anytime the pump is running.
JETS 2 (Two Pump Models)
Press JETS 2 pad to turn on pump two to low speed. Pressing a second time
will turn the pump on high speed. Pressing a third time will turn the pump off.
The high speed of pump two will run for 15 minutes and then switch to low
speed. Once on low speed, the pump will run for 15 minutes and then shut off.
To restart the pump to your desired speed, press the JETS 2 pad. The yellow
LED indictor by the JETS 2 pad will illuminate anytime the pump is running.
AUXILIARY JET CONTROL (Euphoria & Wish)
Your spa may be equipped with either one or two additional jet pump controls.
The controls operate the pumps in the seat adjacent to the controls in the
same manner that the master panel does. Pressing the pad once will turn the jet
pump on low speed, pressing again will turn the jet pump on high speed, and
pressing again will turn the jet pump off. If you are controlling the primary jet
pump, it may continue to run on low speed if the spa is in a filtration cycle or is
calling for heat.
ADAGIO™ II AUDIO SYSTEM (OPTION)
Adagio™ II provides a safe enclosure and convenient remote control for your
iPod/MP3 music player. Please refer to the Poly-Planar SpaTunes™ Audio
System & iPod/MP3 Controller Owner's Manual.
QUIET SOAK
Pressing the QUIET SOAK pad will turn off all pump operation. This is a useful
feature when you want to soak in the hot water with no jets running. The QUIET
SOAK feature will last 60 minutes and then resume normal operation. Pressing
any of the jet pads will override the QUIET SOAK feature and turn on the
M A R Q U I S
pumps. Or you can simply press the QUIET SOAK pad to exit the mode. Turning
the LED lights on and off will not affect the QUIET SOAK mode. The yellow LED
indictor by the QUIET SOAK pad will illuminate anytime this feature is engaged.
Note: If the system is heating it will take a few moments for the quiet soak
feature to engage.
TEMPERATURE DISPLAY AND ADJUSTMENT
Factory Default Settings:
• Temperature: 38°C
To adjust the temperature of the water, press either the TEMP + or TEMP – pad.
The display always shows actual water temperature. The first press of the pad
will display the set temperature and begin to flash. Continue to press the TEMP
+ or TEMP – to reach the desired set temperature. Once the display stops
blinking the new temperature setting will be set. The factory default setting is
38°C. The minimum temperature that can be set is 27°C and the maximum
temperature that can be set is 40°C.
HEAT LIGHT
The HEAT light illuminates when the heater is on. The pump circulates on low-
speed whenever the thermostat calls for heat.
HEAT MODE
Your spa comes preset in the standard heat mode. The heat mode can be
adjusted to one of three different settings.
MODE
To change the mode of operation, press the MODE pad to begin. Pressing the
MODE pad will show the current setting which will begin flashing in the panel
display. To change, press the TEMP – pad to scroll through the selections of
Std, Ecn, and Slp. Once the desired mode is showing in the display press
MODE pad.
Standard Mode (Std)
The spa water heats to the temperature as set on the bather's panel. In this
mode the filtration pump turns on for two minutes every half-hour to "poll" or
check the water. If heat is needed the unit heats to the set temperature. The
LCD window steadily displays the actual temperature in this mode.
Economy Mode (Ecn)
In this mode the spa only heats to the set temperature during a filter cycle. The
LCD window displays "Ec" alternately flashing with the actual temperature when
the spa is up to temperature and "Ec" steadily when the spa's water temperature
is below the set temperature.
Sleep Mode (Slp)
Your spa will maintain a water temperature that is 7°C below the set
temperature. The heater functions only during a filter cycle. The LCD window
displays "SL" flashing alternately with the actual temperature when the spa is up
to set temperature. It displays "SL" steadily when below set temperature.
SMARTCLEAN™ FILTRATION
Your spa is preset at the factory with a default setting to filter itself using the jet
pump on low-speed for two hours (F2) twice (dn) in a 24 hour period. These
settings represent the filter settings necessary for average use. The timing of the
first filter cycle is determined by when the spa was initially energized. The first
cycle begins six minutes after this initial power-up. The second filter cycle begins
12 hours after the first cycle.
Factory Default Settings:
• Filter Cycle Duration: F2 (2 hours)
• Filter Cycles: 2C (twice per day)
To adjust the filter settings
Press the TEMP + or TEMP – pad followed by the JETS 1 pad. This will change
the display to show the current filtration duration setting. Choices will be given in
the display as F1 through F12. "F" refers to filtration and 1-12 represent the
duration of the cycle in hours. Use the TEMP + or TEMP – pad to scroll through
the choices. Once the desired time is reached, press the JETS 1 pad to save
and move to the next setting selection.
The next setting selection will be periods per day that the spa will run. This will
allow you to control when the spa will run a filtration cycle. The display will show
®
S P A S
M A N U A L
6
Tabla de contenido