Installing LP Gas Tank
To operate you will need (1) precision-filled standard grill LP gas
tank (20#) with external valve threads.
Note: An empty standard grill LP gas tank weighs approximately
18 lbs. A precision-filled standard grill LP gas tank should weigh
no more than 38 lbs.
Caution: LP gas tank must be properly
disconnected and removed prior to moving this
grill.

Insert LP Gas Tank

Place precision filled LP gas tank upright into the notches in the right cart frame so the tank
valve is facing the gas line connection.

Secure LP Gas Tank

Secure tank by sliding tank retainer wire over shoulder of LP gas tank.

Connect LP Gas Tank

Before connecting, be sure that there is no debris caught in
the head of the LP gas tank, head of the regulator valve or
in the head of the burner and burner ports.
Connect gas line to tank by turning knob clockwise until it
stops.

Disconnect LP Gas Tank

Before disconnecting make sure the LP gas tank valve is
"CLOSED".
Disconnect gas line from LP gas tank by turning knob
counterclockwise until it is loose.
Caution: LP gas tank must be properly
disconnected and removed prior to moving
this grill.
Need a tank of gas? Try tank exchange service. It's easy, fast, safe,
and available at tens of thousands of conveniently located retail outlets
nationwide. You can purchase a new full tank or exchange your empty for
a precision filled one.
Outdoor LP Gas Barbecue Grill Model No. GBC1030W, GBC1030WRS

Operating Instructions

Checking for Leaks

Burner Connections
1. Make sure the regulator valve and hose connections
are securely fastened to the burner and the tank.
(Figures 1 and 2)
If your unit was assembled for you, visually check
the connection between the burner venturi pipe and
orifice. Make sure the burner venturi pipe fits over
the orifice.
WARNING: Failure to inspect this
connection or follow these instructions
could cause a fire or an explosion
which can cause death, serious bodily
injury, or damage to property.
2. Please refer to diagram for proper installation.
(Figures 1 and 2)
3. If the burner pipe does not rest flush to the orifice,
please contact 1.800.762.1142 for assistance.
Tank/Gas Line Connection
1. Make 2-3 oz. of leak solution by mixing one part
liquid dishwashing soap with three parts water.
2. Make sure control knobs are (OFF) position.
(Figure 3)
3. Turn LP gas tank valve to "OPEN".
4. Spoon leak check solution at all "X" locations
(Figures 1, 2 and 4)
a. If any bubbles appear turn LP gas tank valve to
"CLOSED", reconnect and re-test.
b. If you continue to see bubbles after several
attempts, turn LP gas tank valve to "CLOSED"
and disconnect LP gas tank and contact
1.800.762.1142 for assistance.
c. If no bubbles appear after one minute turn LP gas
tank valve to "CLOSED", wipe away solution and
proceed.

Operating Main Burners

First Use
1. Make sure all labels, packaging and protective films
have been removed from the grill.
2. Remove manufacturing oils before cooking on this
grill for the first time by operating the grill for at
least 15 minutes on (HIGH) with the lid closed. This
will "heat clean" the internal parts and dissipate
odors.
Lighting
1. Open lid. Attempting to light the burner with the
lid closed may cause an explosion!
2. Make sure there are no obstructions of airflow to
the burners. Spiders and insects can nest within
and clog the burner / venturi tube at the orifice. A
clogged burner tube can lead to a fire beneath the
appliance.
3. All control knobs must be in the (OFF) position.
(Figure 3)
4. Turn LP gas tank valve to "OPEN".
5. Select burner to light. Push and turn control knob to
(HIGH).
6. Press the (electronic igniter) button and hold for
up to 5 seconds to light burner.
7. If ignition does not occur in 5 seconds, turn burner
control knob (OFF), wait 5 minutes and repeat
lighting procedure.
8. If igniter does not light burner, use a lit match
secured with the lighting rod provided to light
burners manually. Access the burners through the
cooking grid and heat plates. Position the lit match
near side of the burner. (Figure 5)
Important: Always use the lighting rod provided when
lighting burners with a match.
9. After lighting, observe the burner flame, make sure
all burner ports are lit and flame height matches
illustration. (Figure 6)
Note: Each burner lights independently - repeat steps
5-9 for the other burners.
Caution: If burner flame goes out during operation, immediately turn
the gas "OFF" and open lid to let the gas clear for about 5 minutes
before re-lighting.
Figure 1
Burner
LP Gas Valve
venturi
Connection
pipe
X X
LP Gas
Valve with
Main Burners
Orifice
Figure 2
LP Gas Valve
LP Gas
with Orifice
Connection
X X
Burner
Side Burner
venturi
pipe
Figure 3
Figure 4
X
X
X
X
X
Figure 5
Figure 6
Slight
Flame
Yellow
Slight
Blue
Burner
Dark
Blue

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Gbc1030wrs

Tabla de contenido