Laguna WG 250 Instrucciones página 4

Bombas de agua para jardineria
Ocultar thumbs Ver también para WG 250:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Location
The pump should be placed on a flat, level surface.
Important: To prevent constant clogging of the pump strainer,
install the pump on an elevated surface so that the pump intake
is clear of the pond bottom.
Laguna Water Gardening Pump 250: Because of its size, this pump is
not equipped with a base to attach the unit to its surroundings.
There are three suction cups to secure it to the bottom. Ensure the
area is clear of debris that might be sucked into the input and clog
the impeller.
Laguna Water Gardening Pumps 500, 1000 and 1500: These models
are equipped with a removable base. It can be used with suction
cups (included) to secure to the bottom. Alternately, four holes in
the base unit allow screws to position the pump in the correct
place. Once the base is positioned with either suction cups or
screws, place the pump over the base, output facing in the same
direction as the arrow engraved on the base. Press down and for-
ward to lock the pump to the base.
Laguna Water Gardening Pumps 2000, 3000, 5000 and 7000: The
base is equipped with suction cups, as well as, four holes to allow
the base to be screwed into a piece of wood or other base material.
Once the base has been attached, slide the pump unit onto the
base for a solid platform.
Ensure that the water does not contain particulate matter that may
enter the pump and damage the impeller and motor.
Applications which have very fine grades of mud, sand, or gravel
require an impeller guard or nylon mesh placed over the water intake
to prevent the pump from clogging.
Connect power cord to electrical outlet. In order to start, the pump
must be filled with water. If the unit does not start immediately, tilt
output up slightly to eliminate any air bubbles in the system.
Ensure that the pump is submerged during operation.
The removable pump bases on Laguna Water Gardening Pumps 500,
1000, 1500, 2000, 3000, 5000, 7000 can be secured to a fixed
base. A brick or board will provide a firm platform.
6
CAUTION: LAGUNA WATER GARDENING PUMPS MUST NOT BE
ALLOWED TO RUN DRY.
Rinse pump and impeller after every use.
MAINTENANCE
To avoid injury, do not touch moving or hot parts.
Always unplug all appliances from outlet when not in use, before
putting on or taking off parts and before cleaning
The motor of the Laguna Pump is hermetically sealed and filled
with epoxy, thereby requiring no lubrication or other maintenance.
Although the impeller cavity is self cleaning, regular maintenance is required.
Remove the Laguna Water Gardening Pump from the installation.
Disassemble the complete impeller cavity by first removing the
motor cover.
Removing the motor cover:
Laguna Water Gardening Pumps 250, 500, 1000 and 1500: No tools
needed to remove pump base and motor
cover. Once motor cover is off, move
arrow on impeller cover (WG 500, 1000
and 1500 only) counterclockwise to "off"
position and lift out impeller cover.
Laguna Water Gardening Pumps 2000,
3000, 5000 and 7000: Use a Phillips
(cross headed) Screwdriver to remove
four screws (A) that are attached to the
motor cover (B). (Fig. 1)
Removing the impeller:
Laguna Water Gardening Pumps 250,
500, 1000 and 1500: Remove Impeller
and Ceramic Shaft Assembly - To
remove Ceramic Shaft Assembly, insert
the hooked end of the supplied tool
into the hole near the bottom of the
unit, draw entire assembly up and out.
(Fig. 2)
A
A
B
A
Fig. 1
Fig. 2
7