This airconditioner must be connected to an electrical circuit which includes on building side a 16 A circuit
breaker. It is to place away from easily combustible materials and a free space of 30cm around the appliance.
A 30 mA residual current device is recommended additionally. In case of using an extension cable only use
proper diameters, in case of multiple sockets do not overload it. The airconditioner must be placed on a flat
floor with sufficient load capacity.
INSTALLATION - Installing heat exhaust
1. Choose a place near a window and socket to
place the device.
2. Screw the two plastic exhaust hose ends (figure
1, No. 14) onto the exhaust hose (see figure 2).
3. Install the drainage hose onto the hot air outlet
(10) on the back of the device (see figure 2).
4. Take the window slide set, and pull the inner part
outside until the hole in the outer part is visible.
5. Put the T-bolt from the screw set (16) through
the hole (in the right direction, see figure 3).
6. Push the parts of the window slide set back
together, making sure the T-part of the T-bolt
slides into the slit of the inner part of the window
slide set lengthwise.
7. Screw the butterfly nut from the screw set
loosely onto the T-bolt.
8. Slide the window half open, and place the
window slide set (15) in the frame. The window
slide set can be installed both horizontally and
vertically (see figure 4 and 5).
9. Extend the window slide set so the full width of
the frame is being covered.
10. Fasten the butterfly nut to fix the window slide
set.
11. Close the window as far as the window slide set,
so this covers the window opening completely.
12. Place the device at least 50 cm away from walls
and other objects.
13. Stretch out the exhaust hose, place the flat end
of the hose onto the opening in the window slide
set and fix the hose with the remaining bolt and
ring.
ATTENTION:
To prevent breaking, the exhaust host can only
be twisted or deformed to a certain limit.
The maximal length of the exhaust hose is 150 cm. Do not use extensions or other exhaust hoses; this
can cause serious malfunctions.
To prevent overheating, the outlet of the device must not be blocked.
If you have a tilt window instead of a sliding window, purchase a window sealing kit to close off your
entire window airtight.