Natural Gas Conversion - Ashley Signature P324-776 Guia Del Usuario

Idiomas disponibles

Idiomas disponibles

NATURAL GAS CONVERSION

Natural gas conversion must be performed only by your natural gas provider or
Service Company. Attempting to perform the natural gas conversion yourself is not safe and
may result in property damage, serious bodily injury or death.
Step 1- At the control panel, disconnect the rubber gas hose from the gas valve.
Step 2- Below the burner, disconnect the aluminum gas tube from the orifice elbow.
Step 3- Remove the 2 M4 nuts from the orifice holder and remove the orifice bracket assembly.
Step 4- Disconnect the orifice from the elbow and replace it with the Natural Gas orifice from the kit.
Re-fit the orifice bracket assembly onto the holder using the 2 M4 screw s and nuts. Re- connect
the aluminum gas tube into the end of the elbow. Connect your Natural Gas supply line onto the
gas valve at the control panel. BEFORE ATTEMPTING TO USE THE FIREPIT, check ALL of the
connections for leaks using a solution of soapy water. If a leak is discovered and any bubbles are
seen, close the main gas valve and re-tighten ALL the connections. NEVER USE A FLAME TO
CHECK FOR GAS LEAKS!
P324-776
P a g e 13 of 49