PeakTech 1090 Manual De Instrucciones página 24

Ocultar thumbs Ver también para 1090:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

2.2. PeakTech
LED voltage range
Tolerances
Voltage detection
Polarity detection
Range detection
Response time
ACV Frequency range
Automatic load (RCD)
Internal basic load
Peak current
Operation time
Recovery time
LED on
Single-pole Phase Test
Voltage range
ACV Frequency range
Continuity Test
Resistance range
Test current
Overvoltage protection
Rotary Field Indication
Voltage range (LEDs)
Frequency range
Measurement principle
Self-check Test
Power supply
Power consumption
Temperature range
Humidity
Overvoltage class
®
1095
+/-12, 24, 36, 50, 120, 230, 400,
690 VDC
12, 24, 36, 50, 120, 230, 400,
690 VAC
-30% to 0% of reading
automatic
full range
automatic
< 0.1s LED
50/60Hz
yes
approx. 2.1 W at 600V
1s <0.2A / Is (5s) < 3.5mA
ED =30s
10 min
about 8V AC/DC
100...690 V AC
50/60 Hz
<300 kΩ
5 μA
690 V AC/DC
100...400 V
50/60 Hz
double-pole and contact electrode
autotest
2x1.5 V "AAA" batteries
max.30 mA / approx. 250 mW
-10℃ up to +55℃
< 85% relative humidity
CAT II – 1000 V
-23-
Tabla de contenido
loading

Este manual también es adecuado para:

1095

Tabla de contenido