Maintenance; Troubleshooting - Franklin Electric INLINE PRESSURE Serie El Manual Del Propietario

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

MAINTENANCE

This device is maintenance-free. In case of system maintenance,
review and understand the following safety warnings and product
instructions prior to performing any service.
Hazardous voltage.
Can shock, burn, or cause death.
Ground the device before connecting to
power supply. Disconnect power before
working on the device, pump, or motor.
Hazardous pressure.
Discharge the system before disassembling
the device.
s
WARNING
!
pump, be sure the fuse box leads are disconnected or the
power is turned off. After reassembling the pump, refer to
these instructions before running.
s
WARNING
!
or cause death. Disconnect power to pump before servicing unit.
Problem
Bad electrical connection.
Tripped electrical circuit breaker/fuse.
Pump obstructed.
Pump fails to start or restart
No water flow.
Control unit not installed vertically in proper orientation.
Minimum flow of 0.15 gpm not sustained.
Pump works intermittently
Plumbing or check valve leak
System flow continues above 0.15 gpm.
Device contains debris preventing switch closure.
Pump will not shut off
Control unit not installed vertically in proper orientation.
Plumbing or check valve leak
10
Before disconnecting the
Hazardous voltage can shock, burn,
Probable Causes
Draining
s
NOTICE
!
necessarily drain all other parts of the piping system. If there are
any concerns with the proper procedure or necessity of draining the
suction plumbing, contact a water systems professional.
All piping and water tanks exposed to freezing weather should be
drained. If there are any concerns with the proper procedure to
drain the system's pressure tank, contact the tank manufacturer
for assistance.

TROUBLESHOOTING

If the device and pump do not seem to be operating correctly
together by starting and stopping with water usage, first check
that the technical features of the flow controller and the pump
are compatible. Use the table and figures in this manual to
confirm compatibility.
For the flow control to properly operate the pump system, water
must pass through the device every time water is needed. The water
supply to the device and pump system is typically from a municipal
or utility water main line. The device can also operate on a cistern or
other non-pressurized water tank, but this should be located above
both the pump and the highest water outlet to ensure water flow
through the system.
Troubleshooting
Check the electrical connections.
Check electrical circuit breaker panel.
Check pump and suction line for debris.
Check plumbing and water supply.
Correct installation so that the control device is vertical, with all writing on
the product label in the proper upright position.
Increase water use.
Repair or replace faulty plumbing/check valve
Confirm that there is no water demand.
Check plumbing system for leak.
Clear debris from unit or plumbing.
Correct installation so that the control device is vertical, with all writing on
the product label in the proper upright position.
Repair or replace faulty plumbing/check valve
Disconnecting the pump will not
Corrective Action
Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Inline swcInline swpInline adj

Tabla de contenido