radio: Window Shutter Module
MVr500MrP
5454469 radio: PoWer window shutter module
MVr500MrPX
5454470
Function
This module is used to control and centralise window shutters or curtains either
by means of hard-wired pushbuttons or Yokis remote controls.
Compatibility
The MVR500MRP(X) module is compatible with all three-wire motors
(common, opening, closing). The limit switches may be either electric or
electronic and set on the shutter itself. If mechanical limit switches are used,
the shutter travel is defined by mechanical stops. In this case, the
MVR500MRP(X) module will detect an overload and immediately cut off power
to the motor.
The MVR500MRP(X) module is also compatible with four-wire motors (phase,
neutral, up, down) in permanent up and down control mode.
It is not compatible with tubular motors with integrated radio receiver.

teCHNiCaL SPeCiFiCatioNS

3 or 4-wire motor power
Mains voltage
ambient temperature
relative humidity
Module consumption
radio frequency
dimensions
WIRING
The module must be installed only by qualified personnel and into a place the end-user cannot access, according to the installing national rules. In order to
follow the safety rules, the module must be connected to a power line that is upstream protected by a magnetothermic switch 10A C curve. Wire the module
only when power is off. In three-phase installations the powering phase of the modules and of the driver wire should be the same. Contact Customer Care for
three-phase system wiring diagrams.
1. Connect the mains power between the 'L' and 'N' Terminals.
2. Connect the local pushbutton between the 'L' and 'BP' terminals. Yokis accessory R12M (Code 5454073) must be used to employ a double non-
interlocked pushbutton.
important: check the voltage level between the 'BP' and 'N' terminals on MVr500MrP(X) module if the distance of the pushbutton is
greater than 3 metres. if the voltage is higher than 20V, insert a d600V diode between the return wire of the pushbutton and the 'BP'
terminal of the MVr500MrP(X) module, making sure to connect the white wire of the d600V to the 'BP' terminal.
3. Connect the motor wires to the '3', '4' and '6' terminals. Check that the 'O' terminal is actually connected to the opening wire. Do not rely on the
colours of the motor wires. To check if the motor was connected correctly, carry out 3 short presses on the pushbutton and ensure that the shutter
opens. 4 short presses should cause the shutter to close. If the operation is the opposite of the above, invert the connections of the two motor
wires on the MVR500EMRP(X) module.
DS1054-025B
radio: PoWer window shutter module with
external aerial
230V ~ 2A max. 500VA
230V ~ +10% -15% - 50Hz
-20°C +50°C
from 0 to 70%
0.77W - 3.2VA
2.4GHz
90 x 17.5 x 60 mm
[3.54 x 0.68 x 2.36"]
radio raNGe
PoWer range (*):
• Inside 100 m² apartments with perpendicular
crossing of main wall or ceiling
• 250 m in open range
(Note: in both cases the range may be
reduced by the presence of metallic elements,
crossing of walls or partitions)
radio traNSMiSSioN
the transmitter Led lights up only if the
radio transmission was successful.
Adding an intermediate receiver will solve the
problem of insufficient range.
Refer to the transmitter instruction booklet for
more information.