NuTone InVent AERN100SN Instrucciones De Instalación, Uso Y Cuidado página 7

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

6. Connect wiring.
Bend tab to expose desired access hole. Connect
power cable to housing with appropriate UL approved
connector. Connect black to black, white to white and
green to green or bare wire. Re-install wiring panel and
secure with screw from parts bag.
6
7. Mount fan to ceiling structure.
Mount housing to ceiling structure with standard
drywall or wood screws in locations shown.
*
Center hole optional.
8. Connect 4-in. round duct.
Pull existing ducting through housing discharge
opening.
Attach and tape ducting to duct connector.
Push connector/ducting back through opening.
Engage tabs and secure with screw from parts
bag.
2
4
Install blower. Finish ceiling, then
install grille.
See Steps 8 & 9 on Page 5.
*
3
1
TABS
Tabla de contenido
loading

Tabla de contenido