Electrical installation must be carried out by
licensed, qualified personnel!
Connection of External Price Reduction Control Signal
Optional harness 0020400145C is available for price
Fig.
reduction (promotion) activation. Contact Laundrylux
1
for more information about other timer-based kits that
are available for this function. The harness mates with
a connector on the machine's front main control circuit
board.The price reduction harness carries a +5VDC
signal lead, and a ground lead. When the leads are
connected together (using an external switch or relay
contact), the price reduction mode is activated.
NOTE: Each machine must be connected to a separate
switch or relay contact!! Refer to the machine's operating
manual for information related to programing a discount.
Connection of External Liquid Supply Signals
Fig.
The machine can provide three "trigger signals for
external liquid supply injector pumps. The signals are
2
120V AC, and must, therefore, be routed and connected
in accordance with applicable codes.
Follow the instructions provided in the optional "Liquid
Supply Kit" (PN 096445), to connect the liquid supply
trigger signal harness to CN6 on the power module at
the right-rear corner of the machine, and to your pumps.
The trigger signal harness in the kit has 6 leads,
with signals as follows:
CN6-1: RED WIRE: DETERGENT SIGNAL
CN6-2: BLACK WIRE: BLEACH SIGNAL
CN6-3: BROWN WIRE: SOFTENER SIGNAL
CN6-4, 5, 6: BLUE WIRES: COMMON (120 VAC)
Each trigger signal is activated for 30 seconds at the start of the appropriate segment of a
wash program. Detergent, bleach, and softener are then pumped into the corresponding
compartments of the soap dispenser, which continue to flush for the duration of the fill.
Installation
All optional equipment connected must be
EMC-approved to EN 50081-1 or EN 50082-
2.
Liquid supply signals connector.
CN5
CN4
CN3
CN2
CN1
CN23
CN22
5:1
1
2
CN17 CN18