Zennio ACTinBOX HYBRID AD Manual De Usuario página 55

Actuador knx classic-hybrid
Tabla de contenido
NÚMERO
TAMAÑO
ENT/SAL
FLAGS
112
1 Bit
I
C - - W -
113
1 Bit
I
C - - W -
114
1 Bit
I
C - - W -
115
1 Bit
I
C - - W -
116
1 Bit
I
C - - W -
117
C - - W -
1 Bit
I
118
C - - W -
1 Byte
I
119
1 Byte
I
C - - W -
120
1 Byte
I
C - - W -
121
1 Byte
I
C - - W -
122
1 Byte
I
C - - W -
123
1 Byte
I
C - - W -
124
1 Byte
I
C - - W -
125
1 Byte
I
C - - W -
126
C - - W -
2 Bytes
I
127
2 Bytes
I
C - - W -
128
2 Bytes
I
C - - W -
129
2 Bytes
I
C - - W -
130
2 Bytes
I
C - - W -
131
2 Bytes
I
C - - W -
132
2 Bytes
I
C - - W -
133
2 Bytes
I
C - - W -
134
1 Bit
O
C T R - -
135
1 Bit
O
C T R - -
136
1 Bit
O
C T R - -
137
1 Bit
O
C T R - -
138
1 Bit
O
C T R - -
139
1 Byte
O
C T R - -
http://www.zennio.com
TIPO DE DATO (DPT)
RANGO
[1.001] DPT_Switch
0/1
[1.001] DPT_Switch
0/1
[1.001] DPT_Switch
0/1
[1.001] DPT_Switch
0/1
[1.001] DPT_Switch
0/1
[1.001] DPT_Switch
0/1
[5.010] DPT_Value_1_Uncount
0-255
[5.010] DPT_Value_1_Uncount
0-255
[5.010] DPT_Value_1_Uncount
0-255
[5.010] DPT_Value_1_Uncount
0-255
[5.010] DPT_Value_1_Uncount
0-255
[5.010] DPT_Value_1_Uncount
0-255
[5.010] DPT_Value_1_Uncount
0-255
[5.010] DPT_Value_1_Uncount
0-255
[7.001] DPT_Value_2_Uncount
0 - 65535
[9.001] DPT_Value_Temp
0,00 - 120,00
[7.001] DPT_Value_2_Uncount
0 - 65535
[9.001] DPT_Value_Temp
0,00 - 120,00
[7.001] DPT_Value_2_Uncount
0 - 65535
[9.001] DPT_Value_Temp
0,00 - 120,00
[7.001] DPT_Value_2_Uncount
0 - 65535
[9.001] DPT_Value_Temp
0,00 - 120,00
[7.001] DPT_Value_2_Uncount
0 - 65535
[9.001] DPT_Value_Temp
0,00 - 120,00
[7.001] DPT_Value_2_Uncount
0 - 65535
[9.001] DPT_Value_Temp
0,00 - 120,00
[7.001] DPT_Value_2_Uncount
0 - 65535
[9.001] DPT_Value_Temp
0,00 - 120,00
[7.001] DPT_Value_2_Uncount
0 - 65535
[9.001] DPT_Value_Temp
0,00 - 120,00
[1.001] DPT_Switch
0/1
[1.001] DPT_Switch
0/1
[1.001] DPT_Switch
0/1
[1.001] DPT_Switch
0/1
[1.001] DPT_Switch
0/1
[5.010] DPT_Value_1_Uncount
0-255
VALORES
1ª VEZ
RESET
-
Anterior
[FL] Dato (1bit) 11
-
Anterior
[FL] Dato (1bit) 12
-
Anterior
[FL] Dato (1bit) 13
-
Anterior
[FL] Dato (1bit) 14
-
Anterior
[FL] Dato (1bit) 15
[FL] Dato (1bit) 16
-
Anterior
[FL] Dato (1byte) 1
-
Anterior
-
Anterior
[FL] Dato (1byte) 2
-
Anterior
[FL] Dato (1byte) 3
-
Anterior
[FL] Dato (1byte) 4
-
Anterior
[FL] Dato (1byte) 5
-
Anterior
[FL] Dato (1byte) 6
-
Anterior
[FL] Dato (1byte) 7
-
Anterior
[FL] Dato (1byte) 8
-
Anterior
[FL] Dato (2bytes) 1
-
Anterior
-
Anterior
[FL] Dato (2bytes) 2
-
Anterior
-
Anterior
[FL] Dato (2bytes) 3
-
Anterior
-
Anterior
[FL] Dato (2bytes) 4
-
Anterior
-
Anterior
[FL] Dato (2bytes) 5
-
Anterior
-
Anterior
[FL] Dato (2bytes) 6
-
Anterior
-
Anterior
[FL] Dato (2bytes) 7
-
Anterior
-
Anterior
[FL] Dato (2bytes) 8
-
Anterior
0
Anterior
[FL] RESULTADO Función 1 (1bit)
0
Anterior
[FL] RESULTADO Función 2 (1bit)
0
Anterior
[FL] RESULTADO Función 3 (1bit)
0
Anterior
[FL] RESULTADO Función 4 (1bit)
0
Anterior
[FL] RESULTADO Función 5 (1bit)
0
Anterior
[FL] RESULTADO Función 1 (1byte)
ACTinBOX CLASSIC-HYBRID AD
NOMBRE
FUNCIÓN
Dato de entrada binario (0/1)
Dato de entrada binario (0/1)
Dato de entrada binario (0/1)
Dato de entrada binario (0/1)
Dato de entrada binario (0/1)
Dato de entrada binario (0/1)
Dato de entr. de 1byte (0-255)
Dato de entr. de 1byte (0-255)
Dato de entr. de 1byte (0-255)
Dato de entr. de 1byte (0-255)
Dato de entr. de 1byte (0-255)
Dato de entr. de 1byte (0-255)
Dato de entr. de 1byte (0-255)
Dato de entr. de 1byte (0-255)
Dato de entr. de 2bytes
Dato de entr. de 2bytes
Dato de entr. de 2bytes
Dato de entr. de 2bytes
Dato de entr. de 2bytes
Dato de entr. de 2bytes
Dato de entr. de 2bytes
Dato de entr. de 2bytes
Resultado de la FUNCIÓN 1
Resultado de la FUNCIÓN 2
Resultado de la FUNCIÓN 3
Resultado de la FUNCIÓN 4
Resultado de la FUNCIÓN 5
Resultado de la FUNCIÓN 1
Soporte técnico:
http://zennio.zendesk.com
55
Tabla de contenido
loading

Este manual también es adecuado para:

Zn1io-ab46a

Tabla de contenido