Electrical Equipment; Preliminary Warnings - GiBiDi MINNOW 500 Instrucciones Para La Instalación

Motorreductor electromecánico
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

16
UK

ELECTRICAL EQUIPMENT

1- Gearmotor: power supply,
2- Photocell transmitter 2x0.5mm² cable
3- Photocell receiver 4x0.5 mm² cable
4- Antenna screened coaxial cable.
5- Frame 4x0.5mm² cable
6- Rack
7- Key selector 3x0.5mm² cable
8- 230 Vac flashing light signaller 2x0.75mm² cable
9- Omnipolar magnetothermal switch with minimum contact opening of 3 mm. Power supply line to the control
unit: 220-230V, 50-60Hz, 3x1.5mm²
ELECTRICAL EQUIPMENT
Operator
Type
Supply Voltage
Power adsorbed
Current adsorbed
Thermal cutout
Capacitor
Max speed
Max torque
Operating temperature
Torque adjustment
Degree of protection
Max leaf weight
Operating frequency (%)
Lubrication
Formula to calculate the
operating frequency

PRELIMINARY WARNINGS

Check that the gate structure is in conformity with the regulations in force and that leaf movement is linear without
friction.
Preliminary checks:
check that the gate structure is sufficiently robust. In any case, check that the weight and dimensions of the gate
Ÿ
fall within the limits of use of the operator;
check that the leaf can be moved manually without force (points of greatest friction) for the entire travel of the gate
Ÿ
during both opening and closing;
3x1.5mm²
cable (comply with the current standards)
cable.
A + C
%Fu =
A + C + P
MINNOW 500
Irreversible electromechanical gearmotor
220/230Vac 50-60Hz
250W
MAX 1.1A
140°C
12µF
0,15 m/sec
12 N/m
Elettronica
-20°C + 60°C
IP 44
500 Kg
40% (a 20°C)
Grease
A = Opening time
C = Closing time
x 100
P = Overall pause time
A+C+P = Time between two openings
MINNOW
Tabla de contenido
loading

Tabla de contenido