Technical Data
Code
Description
Disc
Voltage
Frequency
Current
Power
Speed
Duty cycle
Conductors
Insulating
WARNING
it should only be replaced by the manufacturer or at a
The build quality of the electric insulation is altered if spills or liquid gets into the tool while in use.
Do not expose to rain, liquids and/or dampness.
WARNING
Power Requirements
Tools with double insulation and reinforced insulation are
WARNING
equipped with a polarized plug (one prong is wider than the other). This plug will
only fit in the right way into a polarized outlet. If the plug cannot be introduced
into the outlet, reverse the plug. If it still doesn't fit, call a qualified electrician to
install for you a polarized outlet. Do not alter the plug in any way. Both
insulation types eliminate the need of both a grounded third power cord with
three prongs or a grounded power connection.
WARNING
When using an extension cable, verify the gauge is enough for the power that your product needs. A lower
gauge cable will cause voltage drop in the line, resulting in power loss and overheating. The following table shows the right
size to use depending on cable's length and the ampere capability shown in the tool's nameplate. When in doubt use the
next higher gauge.
Ampere
Capacity
from 0 A and up to 10 A
from 10 A and up to 13 A
from 13 A and up to 15 A
from 15 A and up to 20 A
When operating power tools outdoors, use a
WARNING
extension cable labeled "For Outdoors Use". These extensions are specially designed for
operating outdoors and reduce the risk of electric shock.
50 minutes work and 20 minutes idle. Maximum 6 hours per day.
14 AWG x 2C with insulating temperature of 221 °F
Class II
Avoid the risk of electric shock or severe injury. When the power cable gets damaged
Before gaining access to the terminals all power sources should be disconnected.
Number of
Conductors
3 (one grounded)
* It is safe to use only if the extensions have a built-in artifact for over current protection.
AWG = American Wire Gauge. Reference: NMX-J-195-ANCE-2006
ESMA-9N3
12482
Angle grinder
9"
120 V
60 Hz
16 A
2.6 Hp
6 200 RPM
IP Grade
Power cord grips used in this product: Type "Y"
Build quality: Reinforced
Thermal insulation on motor winding: Class E
Extension gauge
from 5.9' to 49.2' |
18 AWG( * )
16 AWG
14 AWG
8 AWG
grounded
IP20
Authorized Service Center.
higher than 49.2'
16 AWG
14 AWG
12 AWG
6 AWG
ENGLISH
3