g� List of alarms / events
Alarm 01: Probe PT100
Alarm 02: Overheating. Tem-
perature above 220°C
Alarm 03: Platen safety sys-
tem triggered
Alarm 06: Upper pressing
sensor not reached
Alarm 07: Lower pressing
sensor not reached
Alarm 08: Right rotation sen-
sor not reached
Alarm 09: Left rotation sensor
not reached
Alarm 10: Communication er-
ror
Alarm 13: Temperature not
reached.
14
Press the red/orange area to clear the fault.
Probe signal lost (sensor or cable). The hea-
ting control is instantly disabled.
Temperature reading above 230°C. The
heating control is instantly disabled.
Detection is immediate. The heating
control and pressing operation are instant-
ly disabled.
Signal not detected after 5 seconds. Caused
by faulty sensor, lack of compressed air sup-
ply, jamming (mechanical, etc).
Signal not detected after 5 seconds. Caused
by faulty sensor, lack of compressed air sup-
ply, jamming (mechanical, etc).
Signal not detected after 5 seconds. Caused
by faulty sensor, lack of compressed air sup-
ply, jamming (mechanical, etc).
Signal not detected after 5 seconds. Caused
by faulty sensor, lack of compressed air sup-
ply, jamming (mechanical, etc).
Communication lost between power board
and screen board.
Contact your stockist.
Blocks first cycle start request. Permits cy-
cle start at second request (forced start
despite setpoint not being reached).