Power Requirements - Truper EXPERT COPLA-60X Instructivo

Cortadora de plasma
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Technical specifications
Open Circuit Voltage
Current Range
Maximum Cutting Capacity
Ideal Cutting Capacity
WARNING
Avoid the risk of electric shock or severe injury. When the power cable gets damaged
it should only be replaced by the manufacturer or at a
The build quality of the electric insulation is altered if spills or liquid gets into the tool while in use.
Do not expose to rain, liquids and/or dampness.
Before gaining access to the terminals all power sources should be disconnected.
WARNING

Power Requirements

WARNING
The tool shall be grounded while in use to prevent an electric shock.
The cutter shall be installed as close as possible to the mains power supply. Check the power supply carries the same
voltage than the one indicated in the motor nameplate.
WARNING
This tool has to be grounded.
The power cables are coded with the following colors:
CAUTION
• - If using the cutter together with more tools having the same ground, connect in parallel, never making a series.
CAUTION
• The ground conductor cable gauge shall not be a lower gauge than the power supply cable.
CAUTION
• Connection to the power supply shall be carried out by a professional electrician.
• Double check the input connection voltage shown in the plasma cutter nameplate matches the power
CAUTION
supply voltage.
• The power supply gauge shall comply with the following requirements
CAUTION
Fuse (rated working current)
Electric Wire
* Fuse fusion current is double than its rated current.
Code
Description
Voltage
Frequency
Current
Work Cycle
The specified output values are given in a 68 °F temperature. With higher temperatures, the work cycle can be reduced.
Air Pressure
Weight
Insulation
Conductors
55 A ( * )
6 mm
2
COPLA-60X
17332
Plasma Cutter
INPUT
220 V
60 Hz
49 A
OUTPUT
305 V c.c.
20 A - 60 A
1"
3/4"
30 % 3 minutes' work per 7 minutes' rest.
50 PSI - 80 PSI
31,74 lb
Class I
3G - 6 mm
with 221 °F insulation
2
Power Cord Grips used is: Type "Y".
Tool Build Quality: Basic Insulation
Thermal insulation on motor winding: Class H
Authorized Service Center.
GREEN
WHITE
BLACK
IP Grade
IP21S
GROUND
CURRENT
CURRENT
ENGLISH
3 3

Capítulos

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

17332

Tabla de contenido