SOG II Typ F Manual De Instrucciones Y Mantenimiento página 2

Ocultar thumbs Ver también para II Typ F:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 7
®
S G
echnology instead of chemicals!
1
Before removing the cassette, the hose must
be pulled forwards out of the cover connec-
tion.
3
Insert cassette, plug (black) off forwards, and
attach the extractor hose onto the cover con-
nection.
Only by door version:
Completely unscrew
the 2 crosshead screws
at the bottom.
Only by floor version:
1.
Before changing the filter, pull the fan out of the rubber sleeve in the filter housing.
2.
Since the filter cartridge push-fits into the pipe, twist it back and forth while pulling it upwards
and out.
3.
Insert the new filter cartridge into the pipe.
4.
You must moisten the rubber sleeve before inserting the fan into the filter cartridge.
5.
Insert the fan as far as it goes, twisting it back and forth.
By roof version:
Operating and Maintenance Intructions
®
®
SOG + SOG II - Type F for all Thetford C250/C260
Change the filter once a year!
Push the cover cap up a
little and remove at the
front.
Change the filter once a year!
maintenance-free
2
Insert black plug in the cover connection. Pull
out the cassette and dispose of at an appro-
priate site.
4
If you want to change a second cassette, then
you can carry the full cassette in the storage
space for several days. (There is no longer any
gas formation if the cassette is full)
Take out the filter and in-
sert a new filter into the
existing fitting.
Place the cover over the top, pulled for-
ward slightly at the bottom. Push the
cover from top to bottom and latch.
Hold in place to insert screws and
tighten gently.
Ventilator
1.
2.
3.
GB
®