INSTALLATION WITH OPTIONAL PEDESTAL BASE OR STACkING kIT

WARNING : If you are installing your dryer using an optional pedestal base or stacking kit, please
refer to Optional Accessories in this manual or to the instructions for your pedestal or stacking kit
before proceeding with the installation.
Recommended installation spacing for cabinet installation
For cabinet installation with a door, minimum ventilation openings in the top of the cabinet
are required.
7"* (17.8 cm)
5"**
(12.7 cm)
Closet ventilation requirements
Closets with doors must have both an upper and lower vent to prevent heat and moisture buildup in
the closet. One upper vent opening with a minimum opening of 48 sq. in. (310 cm
no lower than 6 feet above the floor. One lower vent opening with a minimum opening of 24 sq. in.
(155 cm
) must be installed no more than one foot above the floor. One example shown uses vent
2
grilles in the door.
Recommended installation spacing for recessed or closet
installation, with stacked washer and dryer
The dimensions shown are for the recommended spacing.
7"* (17.8 cm)
9"**
(22.9 cm)
1"**
1"
27"
1"
30"
(76.1cm)
(2.5 cm)
(2.5 cm)
(68.6 cm)
(2.5 cm)
1"* (2.5 cm)
5 "**
1/2
(14 cm)
*Required spacing
** For side or bottom venting, 2 inches
(5.1 cm) spacing is allowed.
) must be installed
2
*Required spacing
** For side or bottom
venting, 2 inches
(5.1 cm) spacing is
77
"
1/2
allowed.
(196.8 cm)