InsTAllATIon InsTRUCTIons:
Carefully review all of these instructions BEFORE proceeding to install and operate your air conditioner unit .
Failure to do so may cause damage, injury, or bodily harm including permanent disability and/or death .
loCATIon:
• The air conditioner should be placed on a firm foundation to minimize noise and virbration . For safe and
secure positioning, place the unit on a smooth, level floor strong enough to support the unit .
• The unit has casters to aid placement, but it should only be rolled on smooth, flat surfaces . Use caution
when rolling on carpet surfaces . Do not attempt to roll the unit over objects .
• The unit must be placed within reach of a properly rated grounded socket .
• Never place any obstacles around the air inlet or outlet of the unit .
• Allow 1 to 3 feet (30cm to 100cm) of space from the wall with for efficient air-conditioning and prevent
overheating .
exhAUsT hose InsTAllATIon:
The exhaust hose and adaptor must be installed or removed in accordance with the usage mode .
InsTAlleD—Cooling, heat pump, or auto mode
ReMoveD—Heating (electric), fan or dehumidify mode
1 . Install the window Exhaust adapter B onto the exhaust hose as shown
in Fig . A or Fig . B . Refer to the previous pages for window kit installation .
2 . Place the Exhaust hose over against the air outlet opening hook and
flat the other end (Figure C) for quick installation .
The exhaust hose can be installed into the wall (ot applicable to the units
without adapter A, expansion plugs and wooden screws of accessories) .
1 . Prepare a hole in the wall . Install the wall Exhaust adapter A onto the
wall (outside) by using 4 expansion plugs and wooden screws, be sure to
fix thoroughly . (see Figure D)
2 . Attach the Exhaust hose to wall Exhaust adaptor A .
noTe: Cover the hole using the adaptor cap when not in use .
The duct can be compressed or extended moderately according to the
installation requirement, but it is desirable to keep the duct length to a
minimum .
IMPoRTAnT: DO NOT OVERBEND OR KINK THE EXHAUST HOSE (see Fig . E)
CAUTIon exhAUsT PoRT
Make sure that there are no obstacles within 18" or 50cm around the exhaust
outlet in order for the exhaust system to work properly .
5