NOCO Genius GENIUS10 Guía Del Usuario Y Garantía página 4

Ocultar thumbs Ver también para GENIUS10:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Mode
Explanation
In Standby mode, the charger is not charging or providing any power to the battery. Energy Save is activated during this mode, drawing microscopic
power from the electrical outlet. Canbus is enabled in Standby mode. When in Standby, the orange Standby LED will illuminate.
Standby
No Power
For charging 12-volt Wet Cell, Gel Cell, Enhanced Flooded, Maintenance-Free and Calcium batteries. When selected, the 12V white LED will illuminate.
14.5V | 10A | Up To 230AH Batteries
For charging 12-volt AGM batteries. When selected, the 12V AGM white LED will illuminate.
14.8V | 10A | Up To 230AH Batteries
For charging 12-volt lithium-ion batteries, including lithium iron phosphate. When selected, the 12V Lithium blue LED will illuminate. For use on batteries
with Battery Management Systems (BMS) only.
14.6V | 10A | Up To 230AH Batteries
For charging 6-volt Wet Cell, Gel Cell, Enhanced Flooded, Maintenance-Free and Calcium batteries. When selected, the 6V white LED will illuminate.
Press & Hold
(3 Seconds)
7.25V | 10A | Up To 230AH Batteries
For charging 6-volt advanced AGM batteries, which requires a higher than normal charging voltage. When selected, a white LED will illuminate.
Press & Hold
(3 Seconds)
7.40V | 10A | Up To 230AH Batteries
Force Mode
For charging batteries with a voltage lower than 1V. Press and Hold for five (5) seconds to enter Force Mode. The selected charge mode will then operate
under Force Mode for five (5) minutes before returning to standard charging in the selected mode.
Press & Hold
(5 Seconds)
10A | Up To 230AH Batteries
Converts to a DC power supply for powering any 12VDC device, like a tire inflator, oil changer, or as a memory retainer when replacing a battery. When
selected, a red LED will illuminate.
13.6V @ 25°C | 10A | Max 12A
An advanced battery recovery mode for repairing and restoring, old, idle, damaged, stratified or sulfated batteries. When selected, a red LED will
illuminate and flash.
16.5V | 10A | Any Capacity
(Peak Voltage Measured At 25°C, Amperage Rating Is Bulk Amperage When Above 0°C)
[Press and Hold 3 Seconds With Clamps Not Connected]
[From Standby Press and Hold 3 Seconds With Clamps Connected to the Battery]

Hide quick links:

Tabla de contenido
loading

Tabla de contenido