Understanding Charge LEDs.
LED
25%
Red LED
50%
Red LED
75%
Orange LED
100%
Green LED
Optimization
Green LED
Understanding Error LEDs.
Error Conditions will be indicated by the following LEDs.
LED
Reason/Solution
Solid
Charger is in Standby mode or Battery voltage is too low for charger to detect.
Solid
Battery voltage is too high for the selected charge mode. Check the battery and charge mode.
Solid
Possible battery short / Battery will not hold a charge. Have battery checked by a professional.
Solid
Reverse polarity. Reverse the battery connections.
Solid
Charger internal temperature too high / Charger will resume function once the Charger internal temperature drops.
Flashing
Charger ambient temperature too cold / Charger will resume function once the Charger ambient temperature rises.
Explanation
The 25% Charge LED will slowly pulse "on" and "off" when the battery is less than 25% charged. When the battery is 25% charged, the
25% LED will go solid and the next LED will begin to pulse.
The 50% Charge LED will slowly pulse "on" and "off" when the battery is 25% - 50% charged. When the battery is 50% charged, the
50% LED will go solid and the next LED will begin to pulse.
The 75% Charge LED will slowly pulse "on" and "off" when the battery is 50% - 75% charged. When the battery is 75% charged, the
75% LED will go solid and the next LED will begin to pulse.
The 100% Charge LED will slowly pulse "on" and "off", when the battery is less than 100% fully charged. When the battery is fully
charged, the Green LED will be solid, and the 25%, 50% and 75% Charge LEDs will turn "off".
During Optimization, the 100% Charge LED will pulse "on" and "off" slowly. Once the battery is fully optimized the 100% Charge LED
will turn solid green. The charger can be left connected to the battery indefinitely.