Check that the unit is levelled and that the environmental conditions meet those indicated in point 4.
If the problem persists despite the above checks, contact your nearest service centre.
Warning: Never approach the motor compartment in the event of leaking gas or a fire. Unplug at the mains. Never use
water to put out any flames, but only dry powder extinguishers.
13 – Accessories
The ERIS displays can be fitted with the following accessories on request.
-
Night cover.
-
Row dividers.
-
Raised plexiglas edges for display shelves.
-
Shelf illumination.
-
Electric defrosting (armoured resistances on the evaporator).
If interested in purchasing any of the above accessories, contact your nearest Oscartielle dealer or Oscartielle S.p.A
directly. Only Oscartielle Customer Service is allowed to fit the defrosting resistances.
14 - Customer service
If you need the assistance of a technician or mechanical, electrical or compressor components need to be replaced,
please contact the dealer from whom you bought the unit and ask for original spare parts.
15 - Dismantling and elimination of cabinet
For environmental reasons and in compliance with the regulations in your country, separate the parts of the cabinet for
disposal and/or recycling.
All the parts that make up the cabinet are made of materials that are not classifiable as urban waste except for the
metallic parts that are not classified as special waste in most countries. As regards the parts of the refrigeration circuit,
that is the refrigerating gas and lubricating oil, these should not be disposed of carelessly and can be recycled by
specialized centers.
This product contains HFC, namely fluoridated gasses, a refrigerating gas with a high Global Warming Potential
(GWP) regulated by the Kyoto protocol.
The gas contained in foam polystyrene for thermal insulation of the cabinet is (R134A).
Oscartielle equips its plug-in cabinets with the following types of refrigerating gasses:
= 1300
R 134a; GWP
(100)
R 404A; GWP
) = 3750
(100
This unit is hermetically sealed and the refrigerating gas load is under 3 kg.
For this reason it is not subject to the requisite of an installation booklet and periodic inspections for leakage of
the refrigerating gas (presidential Decree no. 147 of February 15th 2006, Art. 3 and 4).
16 - Manufacturer's statement (Start-up prohibition)
The above models are also built to be assembled in-line with other items of machinery to produce a machine, as defined
by EEC Directive 89/392.
Therefore, the Manufacturer hereby states that it is not permitted to start the unit up until the machine in which it is
incorporated or will become a part of has been identified and its compliance with the provisions of EEC Directive 89/392
and applicable national laws has been stated. In other words, until the machine referred to in this statement becomes one
with the final machine.
17 - Wiring diagrams
The wiring diagram can be seen on page 5 - FIG.14.
Legend:
AP = Output 230V
CA = Main power supply cable
CE = Electronic control
CS = Connecting cable
D = Defrosting heating element (Optional)
IG = Main switch
IL = Light switch
K1, K2, K3 = Relay
L = Phase
Lu = Lights
M = Motor
N = Neuter
PC = Control panel
QE = Control board
SS = Defrost probe
ST = Temperature probe
Vm = Fan motor
Vv = Display case fan