AUTOMATIC CONDENSATE UNIT
Model: CB25*
23' LIFT
RULES FOR SAFE OPERATION
1.
Carefully read the Owners Manual and rules for safe operation.
2.
All wiring must conform to local codes. Use the National Electric Code if local code is nonexistent.
3.
CAUTION! To reduce risk of electric shock disconnect from power supply before servicing, pull the plug on models which have
plug-in connections.
4.
Do not handle the pump with wet hands or when standing in water as fatal shock could occur. Disconnect main power before
handling unit for ANY REASON!
5.
Protect the power cable from coming in contact with sharp objects.
6.
Do not kink power cable and never allow the cable to come in contact with oil, grease, hot surfaces or chemicals.
7.
Make certain that line voltage conforms to the voltage specified on motor and nameplate.
8.
WARNING! To reduce risk of electrical shock, connect only to a properly grounded grounding type receptacle.
Select a location for the pump. It should be
as near as possible to the air conditioning
coil. The pump must be level. The inlet
hole must be below the coil drain.
Carefully unpack the pump. Remove the
switch cover. Check each float rod for "free"
action.
Owners Manual
Keep For Future Reference
INSTALLATION OPERATION
CAUTION: Read rules for Safe Operation and Installation.
*Suffix denotes features
Example: CB25
1
Base Model
UL Listed
Voltage:
1 = 115V; 2 = 230V: 4 = 460V;
INTRODUCTION
INSTALLATION
CB25
CB50
BECKETT CORPORATION
Irving, Texas
www.beckettpumps.com
Toll Free: 1-888-232-5388
© 2015 BECKETT CORPORATION All Rights Reserved
UL
HT HTS CE
CE Listed
High Temperature Model, for use with Max. 212° F water.
High Temperature Model, for use with Max. 190° F water.
PRIMARY SWITCH
FLOAT
TERMINAL BLOCK
Model: CB50*
48' LIFT
COVER
OUTLET
SAFETY SWITCH
MOTOR
INLET
STAND
TANK
Y8611_RevJ
Tabla de contenido
loading

Resumen de contenidos para Beckett CB25 Serie

  • Página 1 MOTOR Carefully unpack the pump. Remove the CB50 switch cover. Check each float rod for “free” FLOAT action. INLET BECKETT CORPORATION TERMINAL BLOCK STAND Irving, Texas www.beckettpumps.com Toll Free: 1-888-232-5388 OUTLET TANK © 2015 BECKETT CORPORATION All Rights Reserved Y8611_RevJ...
  • Página 2: Maintenance And Troubleshooting

    PIPING Copper Tube Vinyl Hose Run a drain line from the evaporator coil drain to the pump. Use the flexible Grab plastic pipe where the code permits. Evaporator Spacer Set Inner Ring Insert the pipe 1” below the pump (“A” Coil) O Ring cover.
  • Página 3 Retirer le couvercle de l’interrupteur. L’arrivée Vérifier les deux tiges des flotteurs pour Le réservoir s’assurer qu’elles se déplacent librement. Le Flotteur BECKETT CORPORATION La Sortie Irving, Texas La Position www.beckettpumps.com Toll Free: 1-888-232-5388 © 2015 BECKETT CORPORATION All Rights Reserved...
  • Página 4: Entretien Et Dépannage

    TUYAUTERIE Tube de Cuirve Installer une tuyauterie de purge reliant Écrou Tube de Vinyle l’évaporateur à la pompe. Utiliser un tube Anneau Écrou de plastique flexible là où la réglementation de Serrage Anneau Intérieur le permet. Insérer le tube 2,5 cm (1 po) Jeu D’Entretoise sous le couvercle de la pompe.
  • Página 5: Bomba Automática De Condensado

    Desempaque la bomba cuidadosamente. Remueva la cubierta del Primario interruptor. Revise el rotor de cada flotador para ver si tiene acción libre. Tanque BECKETT CORPORATION El Bloque de Terminal Irving, Texas Salida www.beckettpumps.com Flotador Toll Free: 1-888-232-5388 © 2015 BECKETT CORPORATION All Rights Reserved El Soporte...
  • Página 6: Mantenimiento Y Detección De Fallas

    TUBERÍA Tubería de Instale una línea de drenaje desde el drenaje del Tuerca Tubo del Cobre Vinilo serpentín del evaporado hasta la bomba. Donde Tuerca Wacha de Dientes los códigos lo permitan, use tubería de plástico flexible. Inserte el tubo una pulgada debajo de la Wacha Anillo Interno cubierta de la bomba.
  • Página 7 APPLICATION: The warranty covers only properly installed and maintained Beckett products and is limited to application at normal temperature 32º F to 86º F, (0º C to 30º C) pumping fluids with a specific gravity up to 1.1 and with a pH range of 5 to 9 (fresh water). Other liquid applications and extreme temperature uses must be approved in advance by Beckett. The warranty does not apply to or cover damages or defects caused by external causes, including, but not limited to, improper or faulty installation or unauthorized modification, lightning, electrical surges, abuse, misuse or abnormal use or misapplication, including use in a manner inconsistent with the product’s intended function.
  • Página 8 Si el producto se daña en transito, cualquier queja o demanda deber ser presentada con el transportista. REMEDIOS: Si ha existido una falta en la garantía, Beckett, bajo su propia discreción, optará por reparar, reemplazar, o generar un crédito o reembolso para la parte en particular disconforme.

Este manual también es adecuado para:

Cb50 serie

Tabla de contenido