TEST SWITCH/STATUS LED BOARD REPLACEMENT:
After the unit is opened disconnect the connector from Test switch /Status LED board assembly, flex the snap at one side remove
Test switch/Status LED board from plastic cover carefully. Replace new Test switch/Status LED board and push the board towards
plastic cover carefully. Ensure that board is properly assembled then connect connector and close the unit.
To remove IR board, release snaps
Note: PEL units can not be
configured to OEL in the field
AC Input Line
(PEL Units)
Pin 4
Pin 3
Pin 1
AC Input Line Pin Details
Pin 1 White: Neutral
Pin 3 Black: HOT 120-347Vac
Pin 4 Red or Yellow:
Switched-HOT 120-347Vac
AC Input Line
(OEL Units)
Pin 3
Pin 1
AC Input Line Pin Details
Pin 1 White: Neutral
Pin 3 Black: HOT 120-347Vac
AFFINITY
MAINTENANCE and WIRING DIAGRAM
Connector

WIRING DIAGRAM

Heater Connector
(CW Optional Only)
Note (PEL): For switched line applications
only the PEL unit(s) shall be connected.
No other switched products shall be
connected on the switched leg.
®
LIFE SAFETY SOLUTIONS
TEL: 800-705-SERV (7378)
Battery
WT Lamp
Federal Communications Commission (FCC) Requirements:
This device complies with FCC Title 47, Part 15, Subpart B. This
device does not cause harmful interference.
www.lithonia.com
Day Light Sensor
Programming
Connector
Status LED/
Test Switch/
Infrared
activator Board
WT Lamp
© 2020, Acuity Brand Lighting,Inc.
All Rights Reserved.
912-00020-001
Rev. D, 3/2021