QL Thruster requirements
Thruster
Motor
BP300
12 V / 2 kW 1 - 10
10 - 20 33 - 67
BP800
12 V / 5 kW 1 - 10
10 - 20 33 - 67
BP800
24 V / 5 kW
1 - 10
10 - 20 33 - 67
BP1200
24 V / 7 kW 1 - 10
10 - 20 33 - 67
BP1300
24 V / 7 kW 1 - 10
10 - 20 33 - 67
CT600
12 V / 4 kW 1 - 10
10 - 20 33 - 67
CT600
24 V / 4 kW
1 - 10
10 - 20 33 - 67
CT900
12 V / 4 kW 1 - 10
10 - 20 33 - 67
CT900
24 V / 4 kW 1 - 10
10 - 20 33 - 67
SP600
12 V / 4 kW 1 - 10
10 - 20 33 - 67
SP600
24 V / 4 kW
1 - 10
10 - 20 33 - 67
SP900
12 V / 5 kW 1 - 10
10 - 20 33 - 67
SP900
24 V / 5 kW 1 - 10
10 - 20 33 - 67
SP1300
24 V / 7 kW 1 - 10
10 - 20 33 - 67
1) The distance from the thruster unit to the battery, one way, each cable.
Use of even larger cable dimensions and larger battery capacity may improve thruster performance.
2) Wiring insulation rating is 105°C (221°F) minimum.
All manuals and user guides at all-guides.com
Maximum
1)
cable length
-- minimum
cable dimension.
1)
2)
Length
Dim.
2
m
ft
mm
AWG
1 - 33
70
95
1 - 33
120
150
300MCN 300 Ah/12 V
1 - 33
95
120
1 - 33
95
120
1 - 33
95
120
1 - 33
95
120
1 - 33
95
95
1 - 33
95
120
1 - 33
95
120
1 - 33
70
95
1 - 33
70
95
1 - 33
120
150
300MCN 300 Ah/12 V
1 - 33
95
120
1 - 33
95
120
Required
minimum
battery capacity
Ah
CCA
(SAE)
2/0
3/0
50 Ah/12 V
550
4/0
1700
3/0
4/0
150 Ah/24 V
1050
3/0
4/0
175 Ah/24 V
1150
3/0
4/0
175 Ah/24 V
1150
3/0
4/0
100 Ah/12 V
800
3/0
3/0
100 Ah/24 V
800
3/0
4/0
150 Ah/12 V
1050
3/0
4/0
150 Ah/24 V
1050
2/0
3/0
100 Ah/12 V
800
2/0
3/0
70 Ah/24 V
625
4/0
1700
3/0
4/0
150 Ah/24 V
1050
3/0
4/0
175 Ah/24 V
1150
English
Required
fuse amp.
200 A (P/N 41100904)
400 A (P/N 41100907)
350 A (P/N 41100906)
400 A (P/N 41100907)
400 A (P/N 41100907)
350 A (P/N 41100906)
300 A (P/N 41100905)
400 A (P/N 41100907)
300 A (P/N 41100905)
300 A (P/N 41100905)
300 A (P/N 41100905)
400 A (P/N 41100907)
350 A (P/N 41100906)
400 A (P/N 41100907)
11